User controls
m Power-on switch
m Automatic degauss at power-up; manual degauss by turning power switch
off, then on (capable of full degauss after monitor is turned off for 20
minutes or more)
m Controls: Brightness, Contrast, Horizontal shift, Vertical shift, Horizontal
size, Vertical size
Active video image area
m Adjusted at the factory for the following standard modes:
Mode
Resolution
Vertical refresh rate
Horizontal scan rate
(hertz)
(kilohertz)
VGA
640 x 480
60
31.5
Macintosh
640 x 480
66.67
35.0
SVGA
800 x 600
60
37.9
Macintosh
832 x 624
75
49.7
Note: Do not choose the 800 x 600, 72-Hz setting. It has not been optimized for this display.
Input electrical requirements
m Voltage
90–132 volts (V), 198–264 V
m Frequency
47–63 hertz (Hz)
m Power
75 watts (W) maximum