beautypg.com

General information, Overall dimensions, Note – Bosch NGM User Manual

Page 5: Preparation, Electrical requirements, Gas requirements, Cabinet requirements

background image

English 3

General Information

Overall Dimensions

NOTE:
These are overall dimensions NOT cutout dimensions.

Preparation

Electrical Requirements

This appliances requires a 60 Hz, 15 Amp, 120 VAC
connection. Plan the installation so that the power
connection is accessible from the front of the cabinet.

Gas Requirements

Supply Pressure:

Natural Gas - 7 inches water column (14.9 Millibars)
minimum.

Propane Gas -11 inches water column (27.4 Millibars)
minimum.

The propane gas tank must be equipped with its own high
pressure regulator in addition to the pressure regulator
supplied with this unit. The cooktop is shipped from the
factory for use with natural gas. For use with LP conversion
kit – Model NEZ1054, must be purchased separately. A
qualified technician or installer must do the conversion.

Cabinet Requirements

Dimension requirements in Figures 1 and 2 are for
combustible surfaces. When the surface is protected by a

material listed by UL as a Floor Protector and Wall Shield
covered with not less than No. 28 MSG sheet metal 0.015
inch (0.38mm) stainless steel, 0.024 inch (0.6mm)
aluminum or copper, it is considered noncombustible and
some dimensions may be reduced. For a noncombustible
surface over the cooktop, the minimum clearance is 24"
(61cm) rather than 30" (76cm).

Instructions are based on standard American cabinets
36" high (91cm) x 24" deep (61cm) with a 25" (63cm)
countertop.

Provide approximately a 10 square inch opening

(65cm

2

) in the toe kick area or other cabinet area for

adequate air inlet to the cabinet if installed with a
downdraft.

The maximum depth of cabinet installed above cooktop
is 13” (33cm).

NOTE:
All measurements given have to be precisely followed. If
nonstandard cabinets are used, make sure they are
installed with minimum dimensions shown in figure 1 and
figure 2.

Plan the installation of the unit so that the power cord, gas
shut-off valve and gas pressure regulator are accessible
from the front of cabinet.

30” Models

36” Models

Width
(Side to Side)

31” (788 mm)

37” (940 mm)

Depth
(Front to Back)

21 1/4” (540
mm)

21 1/4” (540
mm)

Height
(Top to Bottom)

3 13/16 (97 mm)

3 13/16 (97 mm)

Figure 1:

Installed Dimensions (from cooktop edges

)

Depth from Back Wall

Cabinet 13" (33cm) max.

Hood Depth - 24" (61cm) max.

Centered Over Cooktop

Rear Wall - 2" (5cm)

Right Side

12" (33cm) min.

Left Side

12" (33cm) min.

18" (46cm) min.

Above Counter - 30" (76 cm) min. to

Combustible Surface

NGM30 - 30" (76cm) min.

NGM36 - 36" (91cm) min.