FAA APPROVED INSTALLATION MANUAL FOR THE EGT-701 Report 103


INSTALLING THE EGT-701 SCANNER®
1/20/09

Rev-E Page 19 of 30

Setting the Alarm Limits

Turn on the EGT-701 and after self-test, press STEP until the instrument is cycling normally.
To start the Alarm Limit Procedure, with the EGT-701 powered up, do the following:





Hold both

buttons for 5

seconds until

the words

FAC LIM

Tap STEP

button until

the words

END Y

Hold both

buttons for 5

seconds until

the word

PROGRAM

Tap the STEP button to advance to the next item in the list. Tap the LF button to select alternate values of that item. Hold the LF
button to rapidly back up. Prompts listed in the first column are displayed for only two seconds.
Changing the Alarm Limits:

STEP to next

item

LF sequences through these values

Description

FAC LIM

Factory Limits.

FAC? N

 FAC? Y

Restore factory defaults

REV X.XX

Firmware rev. number.

TYPE K

TYPE K

 TYPE J

Hold STEP and LF for five seconds to toggle

Type K or Type J CHT probes. USE THIS WITH CAUTION.*

EGT-CHT

ENG F

 ENG C

Select F or C degrees for all engine temps.

BATTERY

I0.0 H BAT

 35.0 H BAT

Battery high voltage limit, set in 0.5 volt increments.

8.5 L BAT

 30.0 L BAT

Battery low voltage limit.

EGT DIF

30 DIF

 990 DIF

EGT difference limit set in 10° increments.

CHT HI

90 H CHT

 500 H CHT

CHT high limit set in 5° increments.

COOL CHT

-5 CLD

 -200 CLD

Cooling limit set in 5°/min. increments.

TIT HI

650 TIT

 2000 TIT

Both EGT and TIT hi limits are the same.

OIL TEMP

40 H OIL

 500 H OIL

Oil temperature high limit, set in 5° increments.

I0 L OIL

 250 L OIL

Oil temperature low limit set in 5° increments

OIL PRESS

Oil pressure low limit

FUEL FLW

FUEL GAL

FUEL KGSFUEL

LTR

FUEL LBS

Selects the units in all parameters where fuel quantity or
fuel rate is displayed

MAIN TK

MAIN

=50

Main tank capacity, in units selected

AUX TNK

AUX? N

AUX? Y

Y - Yes - aircraft has auxiliary tanks

AUX

=0

Auxiliary tank capacity

LO TIME

MIN

=45

Alarm limit in minutes for low time in tanks

LO FUEL

REM

=I0

Alarm limit for low fuel quantity in tanks, in units selected

CARB? N

CARB? Y

Y - Yes: carbureted engine

RECRD?

RECRD? Y

RECRD? N

Data Recording Option Y-only data recording. N – Only real-
time data output.

END Y

 END N

Y - Yes to exit; N - No to review list again

*CHT will read incorrectly if the wrong probe type is selected. Type K probes generally have red and yellow wires; type J probes
have black and white wires.