27) Weight and Balance Data

TSO C43b, Temperature Indicator EGT-701

30 oz. / 1.9 lbs

EGT probe MM-111

2.0 oz. Each / 0.125 lbs

CHT probe 5050

1.5 oz. each / 0.094 lbs

Wire P.N. WK.-24 Harness 8 ft.

14.0 oz. each / 0.88 lbs

RPM, MAP, and Oil pressure

1.5 oz each / .094 lbs


40

CHANGING THE PROGRAMMED LIMITS

Setting the K-factor (Fuel Flow Option)

You must set the K factor before using the EGT-701 with fuel flow. Note the K-factor that was engraved on the fuel flow
transducer.

1. Turn on the EGT-701 and after self-test, press STEP until the instrument is cycling normally.
2. Place the select toggle switch in the FF position.
3. Start the Pilot Programming Procedure by simultaneously holding the STEP and LF buttons for five seconds. You

will see the word PROGRAM for two seconds.

4. Tap the STEP button repeatedly until you see KF-SET.
5.

Hold STEP and LF for five seconds. First digit blinks: 29.00

6.

Tap or Hold LF to change flashing digit (for example): I9.00

7.

Tap STEP for next digit: I9.00

8.

Tap or Hold LF to change flashing digit: I8.00

9.

Tap STEP for next digit: I8.00

10. Repeat steps 7 and 8 for the remaining two digits.
11. Verify the K-factor that was engraved on the fuel flow transducer is now displayed.
12. Hold STEP and LF for five seconds to exit.
13. Tap STEP

Setting the Data Recording Option Parameters

(Data Recording Option only)
If you haven’t already done so, start the pilot programming procedure; simultaneously hold the STEP and LF buttons
for five seconds. You will see the word PROGRAM for two seconds. To change the date, time and user id for the Data
Recording Option, tap the STEP button until the display shows DUMP? N. Next, simultaneously hold the STEP and
LF buttons for five seconds. Then set the date and time as show below

Tap STEP to

next item

LF sequences
through these values

Comments

MNTH

I

 I2

Month

DAY

I

 3I

Day

YEAR

80

 79

1980 through 2079

HOUR

OO

 23

24 hour time. We suggest you set Zulu time.

MIN

OO

 59

Tapping the step will also zero the seconds (not shown)

USER ID

N I2345

Hold both STEP and LF buttons simultaneously until the first character flashes.
Use LF to select the first character. STEP moves to the next character.

Hold both STEP and LF to exit.