CHIMNEY FLASHING - UPHILL AND DOWNHILL
The uphill flashing will be 4” wider than the width of the
curb (2” on each side). Cut an 1/8” slot in the two uphill
corners of the panel slightly wider than 2 1/16”, so the
uphill flashing can slide through the two slots.
22
CHIMNEY INSTALLATION
Details are subject to change without prior notice.
1. Trim both ends of the uphill and downhill
sides of the flashing as indicated.
2. Slide the uphill flashing into the slots of the roofing
and apply liberal amount of tube caulk.
NOTE: Alternate trim profiles are acceptable using the screw
pattern shown.
DOWNHILL
UPHILL
UPHILL
NOTE: To comply with Texas Windstorm Certification
Testing, #12x11 SDT Type A screws must be used in place
of the #9 Woodgrip screws.