background image

19

PureFlow AirDog

AirDog

®

FP-100 & FP-150 Dodge 1998.5 - 2004

Section 5-E High Flow Suction Tube

INSTALLING THE HIGH FLOW SUCTION TUBE, C

ont’d


5E-10. If the fuel tank was dropped to install the

suction tube, re-install the fuel tank.

If the truck bed was removed, reinstall

the bed.

Section 6 Electrical Harness

The AirDog

®

is equipped with a relay controlled wiring harness.

When properly installed, the AirDog

®

is controlled by the ECM.

WIRING DIAGRAM (In Red)











Figure 44

The AirDog

®

is activated by the ECM through a relay controlled wiring harness connecting

directly to the original Deutsch ECM pump connector.





Figure 45