Connecting regulator to gas supply – L.B. White 350 Premier Dual Fuel User Manual
Page 9
PROPANE H
HEATERS
1. Open the tank’s cover.
2. Assemble bushing, pigtail connector and regulator as
shown. Tighten connections securely. See Fig. 2.
3. Form the connector to ensure the regulator will be
supported by the tank, and the tank valve cover will
protect the regulator from weather conditions.
FIG. 2
4. Thread connector’s POL fitting counter-clockwise into
the tank valve. Tighten securely. See Fig. 2.
5. Open the tank valve.
6. Check all connections with an approved leak detector.
Close the tank cover.
7. When storing or transporting the heater, ensure the
connector’s fitting is protected from damage and dirt
entry.
NATURAL G
GAS H
HEATERS
---
The regulator only should be used if the supply
pressure to the heater is above the maximum inlet
pressure stated on the heater’s dataplate.
----
Connect the regulator to the natural gas supply line.
Gas supply pressure to the regulator must be a
minimum of 2 PSI.
CONNECTING REGULATOR TO GAS SUPPLY
9
3/4x 1/4 BUSHING
PIGTAIL CONNECTOR
POL
- AW060 (18 pages)
- AW325 (18 pages)
- AW250 (18 pages)
- AD250(Spark Ignition) (30 pages)
- AB250 (18 pages)
- AW250(building controller) (31 pages)
- AD250 (31 pages)
- AW250(Smart Box controller) (31 pages)
- FA-MCS-D (21 pages)
- FA-MCS (22 pages)
- COMBO-MCS (23 pages)
- AD060 (30 pages)
- 60 Classic (16 pages)
- 115 Classic (16 pages)
- 170 Classic (16 pages)
- Pilot (94 pages)
- I-17 Infraconic Spark Ignition (28 pages)
- I-17 Infraconic Spark Ignition (26 pages)
- I-3 Infraconic (26 pages)
- I-5 Infraconic (24 pages)
- I-17 Infraconic (28 pages)
- Guardian with Smart Sense - Hot Surface (60K / 100K) (31 pages)
- Guardian with Smart Sense - Spark Ignition (60K / 100K) (31 pages)
- Guardian with Smart Sense / Direct Connect - Spark Ignition (250K) (30 pages)
- 100 Tradesman Portable Forced Air (24 pages)
- 170 Tradesman Portable Forced Air (28 pages)
- 400 Tradesman Portable Forced Air (30 pages)
- Portable Gas Heaters (99 pages)
- 45-75K Tradesman (30 pages)
- HW 120 Therma Grow (28 pages)
- HW120 Plus Therma Grow (30 pages)
- 220 Therma Grow (30 pages)
- 220 Plus Therma Grow (32 pages)
- 300 Director (27 pages)
- 80 Premier (34 pages)
- 170 Dual Fuel (30 pages)
- 350 Premier (33 pages)
- 100 Workman - Standard LP (18 pages)
- 100 Workman - NG Low Pressure (18 pages)
- 250 Norseman (18 pages)
- 200 Norseman (18 pages)
- 225 Workman (18 pages)
- 322 Norseman - Horizontal (18 pages)
- Sentinel Radiant Tube AT150 40' Center Mount (32 pages)