Air proving switch, Fan motor – L.B. White 350 Premier Dual Fuel User Manual
Page 17
1. Remove the mounting screws. Turn switch assembly
so the paddle on the switch arm can be pulled
through oblong hole on side of fan housing. See Fig.
19.
2. Disconnect the leads from the air proving switch.
FIG. 19
AIR PROVING SWITCH
17
OBLONG HOLE
1. Remove belt guard from heater.
2. Remove fan belt.
3. Remove motor pulley from motor and mounting
hardware. See Fig. 17.
FIG. 17
4. Open electrical supply access panel on motor and
disconnect power supply wiring. See Fig. 18.
FIG. 18
■
Ensure motor and fan pulleys are properly aligned
before tightening pulleys to motor shaft.
■
Refer to alignment procedures within manual
■
Motor bearings are permanently lubricated.
FAN MOTOR
HARDWARE
See also other documents in the category L.B. White Radiators:
- AW060 (18 pages)
- AW325 (18 pages)
- AW250 (18 pages)
- AD250(Spark Ignition) (30 pages)
- AB250 (18 pages)
- AW250(building controller) (31 pages)
- AD250 (31 pages)
- AW250(Smart Box controller) (31 pages)
- FA-MCS-D (21 pages)
- FA-MCS (22 pages)
- COMBO-MCS (23 pages)
- AD060 (30 pages)
- 60 Classic (16 pages)
- 115 Classic (16 pages)
- 170 Classic (16 pages)
- Pilot (94 pages)
- I-17 Infraconic Spark Ignition (28 pages)
- I-17 Infraconic Spark Ignition (26 pages)
- I-3 Infraconic (26 pages)
- I-5 Infraconic (24 pages)
- I-17 Infraconic (28 pages)
- Guardian with Smart Sense - Hot Surface (60K / 100K) (31 pages)
- Guardian with Smart Sense - Spark Ignition (60K / 100K) (31 pages)
- Guardian with Smart Sense / Direct Connect - Spark Ignition (250K) (30 pages)
- 100 Tradesman Portable Forced Air (24 pages)
- 170 Tradesman Portable Forced Air (28 pages)
- 400 Tradesman Portable Forced Air (30 pages)
- Portable Gas Heaters (99 pages)
- 45-75K Tradesman (30 pages)
- HW 120 Therma Grow (28 pages)
- HW120 Plus Therma Grow (30 pages)
- 220 Therma Grow (30 pages)
- 220 Plus Therma Grow (32 pages)
- 300 Director (27 pages)
- 80 Premier (34 pages)
- 170 Dual Fuel (30 pages)
- 350 Premier (33 pages)
- 100 Workman - Standard LP (18 pages)
- 100 Workman - NG Low Pressure (18 pages)
- 250 Norseman (18 pages)
- 200 Norseman (18 pages)
- 225 Workman (18 pages)
- 322 Norseman - Horizontal (18 pages)
- Sentinel Radiant Tube AT150 40' Center Mount (32 pages)