Igniter assembly, Fig. 20, Fig. 21 – L.B. White 350 Premier Dual Fuel User Manual
Page 18: Fig. 22
18
IGNITER ASSEMBLY
1. Remove burner access panel. See Fig. 20.
FIG. 20
2. The igniter assembly is located at the top of the
burner casting. Remove the screws securing the
mounting bracket to the burner. See Fig. 21.
FIG. 21
3. Disconnect high voltage ignition lead from igniter
assembly. Remove the screws. See Fig. 22.
FIG. 22
■
The igniter and ground rod should be cleaned during
routine maintenance to maintain proper ignition.
-- Use steel wool or emery cloth.
-- Rub briskly to remove buildup of dust, dirt , and
oxide.
■
Check the igniter’s ceramic base for cracks.
-- Replace the igniter if cracks are found.
SCREWS
IGNITION
LEAD END
ELECTRODE GAP IS 1/8 IN
AND CENTERED OVER BURNER PORT
BURNER
PORT
TOP VIEW
ELECTRODE GAP IS 1/8 in.
AND CENTERED OVER BURNER PORT
FRONT VIEW
5/32 IN IGNITOR BOTTOM
TO BURNER TOP
SCREWS
MOUNTING
BRACKET
IGNITOR/SENSOR
IGNITOR CABLE
5/32 in.IGNITER BOTTOM
TO BURNER TOP
- AW060 (18 pages)
- AW325 (18 pages)
- AW250 (18 pages)
- AD250(Spark Ignition) (30 pages)
- AB250 (18 pages)
- AW250(building controller) (31 pages)
- AD250 (31 pages)
- AW250(Smart Box controller) (31 pages)
- FA-MCS-D (21 pages)
- FA-MCS (22 pages)
- COMBO-MCS (23 pages)
- AD060 (30 pages)
- 60 Classic (16 pages)
- 115 Classic (16 pages)
- 170 Classic (16 pages)
- Pilot (94 pages)
- I-17 Infraconic Spark Ignition (28 pages)
- I-17 Infraconic Spark Ignition (26 pages)
- I-3 Infraconic (26 pages)
- I-5 Infraconic (24 pages)
- I-17 Infraconic (28 pages)
- Guardian with Smart Sense - Hot Surface (60K / 100K) (31 pages)
- Guardian with Smart Sense - Spark Ignition (60K / 100K) (31 pages)
- Guardian with Smart Sense / Direct Connect - Spark Ignition (250K) (30 pages)
- 100 Tradesman Portable Forced Air (24 pages)
- 170 Tradesman Portable Forced Air (28 pages)
- 400 Tradesman Portable Forced Air (30 pages)
- Portable Gas Heaters (99 pages)
- 45-75K Tradesman (30 pages)
- HW 120 Therma Grow (28 pages)
- HW120 Plus Therma Grow (30 pages)
- 220 Therma Grow (30 pages)
- 220 Plus Therma Grow (32 pages)
- 300 Director (27 pages)
- 80 Premier (34 pages)
- 170 Dual Fuel (30 pages)
- 350 Premier (33 pages)
- 100 Workman - Standard LP (18 pages)
- 100 Workman - NG Low Pressure (18 pages)
- 250 Norseman (18 pages)
- 200 Norseman (18 pages)
- 225 Workman (18 pages)
- 322 Norseman - Horizontal (18 pages)
- Sentinel Radiant Tube AT150 40' Center Mount (32 pages)