5 event information, Event information – AKiTiO Taurus Super-S3 LCM User Manual
Page 16
Taurus Super-S3 LCM
Page 14
3.5 Event Information
In addition to the details about the hardware and device configuration, the LCD display will also
show certain event information. Following is a list of possible messages and their meanings.
•
[HDD Error or No Interface]
The alarm goes off and this message shows when (A) only one drive (or none) is installed and
(B) when the power is turned on before the interface cable is connected to the computer and
before the computer is turned on.
Press the [OK] button to temporarily mute the alarm and make sure the device is connected to
the computer.
Note: It is normal for this message to appear for a few seconds when the unit is switched on.
•
[RAID Warning / Degraded Array]
When one of the drives fails, the alarm will go off and the display shows this message.
Press the [OK] button to temporarily mute the alarm and then use the
to locate the defective drive.
•
[XX Cable / Connected]
Shows which cable has been connected.
•
[Cable / Disconnected]
Shows when the cable has been unplugged.
•
[Rebuilding… / Hrs left xhxxmin]
Shows during the rebuild process of a RAID 1 array with an approximate time in hours and
minutes indicating how long it takes until the backup is done.
•
[Detecting Disk / Starting…]
Shows during start up of the system.
•
[XX / Starting …]
Shows during start up of the system.