Physical data – Bryant 582A User Manual
Page 4
PHYSICAL DATA
UNIT SIZE 582A
018040
024040
024060
030040
030060
036060
036090
042060
042090
NOMINAL CAPACITY (ton)
1
1
/
2
2
2
2
1
/
2
2
1
/
2
3
3
3
1
/
2
3
1
/
2
OPERATING WEIGHT (lb)
249
280
280
280
280
314
314
355
355
COMPRESSOR(S) – QUANTITY
Reciprocating-1
REFRIGERANT
(R-22)
Quantity (lb)
2.6
3.5
3.5
3.65
3.65
3.75
3.75
5.7
5.7
REFRIGERANT METERING DEVICE
Acutrol™ Device
Orifice ID (in.)
.034
.034
.034
.034
.034
.032
.032
.034
.034
CONDENSER COIL
Rows—Fins/in.
1—17
1—17
1—17
1—17
1—17
1—17
1—17
1—17
1—17
Face Area (sq ft)
6.1
9.1
9.1
9.1
9.1
9.1
9.1
9.1
9.1
CONDENSER FAN
Nominal Cfm
2000
2400
2400
2400
2400
3000
3000
3000
3000
Diameter
22
22
22
22
22
22
22
22
22
Motor Hp (Rpm)
1
/
8
(825)
1
/
8
(825)
1
/
8
(825)
1
/
8
(825)
1
/
8
(825)
1
/
4
(1100)
1
/
4
(1100)
1
/
4
(1100)
1
/
4
(1100)
EVAPORATOR COIL
Rows—Fins/in.
2—15
2—15
2—15
2—15
2—15
3—15
3—15
4—15
4—15
Face Area (sq ft)
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
EVAPORATOR BLOWER
Nominal Airflow (Cfm)
600
800
800
1000
1000
1200
1200
1400
1400
Size (in.)
10 x 10
10 x 10
10 x 10
10 x 10
10 x 10
11 x 10
11 x 10
11 x 10
11 x 10
Motor (Hp)
1
/
4
1
/
4
1
/
4
1
/
4
1
/
4
1
/
2
1
/
2
3
/
4
3
/
4
FURNACE SECTION*
Burner Orifice No. (Qty—Drill Size)
Natural Gas
2—44
2—44
2—38
2—44
2—38
2—38
3—38
2—38
3—38
Burner Orifice No. (Qty—Drill Size)
Propane Gas
2—52
2—52
2—46
2—52
2—46
2—46
3—46
2—46
3—46
RETURN-AIR FILTERS (in.)†
Throwaway Size
20 x 20 x 1
20 x 20 x 1
20 x 20 x 1
20 x 20 x 1
20 x 20 x 1
20 x 24 x 1
20 x 24 x 1
20 x 24 x 1
20 x 24 x 1
UNIT SIZE 582A
048090
048115
048130
060090
060115
060130
NOMINAL CAPACITY (ton)
4
4
4
5
5
5
OPERATING WEIGHT (lb)
415
415
415
450
450
450
COMPRESSOR(S) – QUANTITY
Scroll-1
Reciprocating-1
REFRIGERANT
(R-22)
Quantity (lb)
6.0
6.0
6.0
8.0
8.0
8.0
REFRIGERANT METERING DEVICE
Acutrol Device
Orifice ID (in.)
.032
.032
.032
.030
.030
.030
CONDENSER COIL
Rows—Fins/in.
1—17
1—17
1—17
2—17
2—17
2—17
Face Area (sq ft)
12.3
12.3
12.3
12.3
12.3
12.3
CONDENSER FAN
Nominal Cfm
3600
3600
3600
3600
3600
3600
Diameter (in.)
22
22
22
22
22
22
Motor Hp (Rpm)
1
/
4
(1100)
1
/
4
(1100)
1
/
4
(1100)
1
/
4
(1100)
1
/
4
(1100)
1
/
4
(1100)
EVAPORATOR COIL
Rows—Fins/in.
3—15
3—15
3—15
4—15
4—15
4—15
Face Area (sq ft)
4.7
4.7
4.7
4.7
4.7
4.7
EVAPORATOR BLOWER
Nominal Airflow (Cfm)
1600
1600
1600
2000
2000
2000
Size (in.)
11 x 10
11 x 10
11 x 10
11 x 10
11 x 10
11 x 10
Motor (Hp)
3
/
4
3
/
4
3
/
4
1.0
1.0
1.0
FURNACE SECTION*
Burner Orifice No. (Qty—Drill Size)
Natural Gas
3—38
3—33
3—31
3—38
3—33
3—31
Burner Orifice No. (Qty—Drill Size)
Propane Gas
3—46
3—42
3—41
3—46
3—42
3—41
RETURN-AIR FILTERS (in.)†
Throwaway Size
24 x 30 x 1
24 x 30 x 1
24 x 30 x 1
24 x 30 x 1
24 x 30 x 1
24 x 30 x 1
*Based on altitude of 0 to 2000 feet.
†Required filter sizes shown are based on the larger of the ARI (Air Conditioning & Refrigeration
Institute) rated. The filter rack is field convertible to hold a field supplied 2 in. filter.
4