Bryant 582A User Manual
Page 14
PERFORMANCE DATA (cont)
DRY COIL AIR DELIVERY*—HORIZONTAL AND DOWNFLOW DISCHARGE
(Deduct 10% for 208 v)
230 AND 460 VOLT
Unit
582A
Motor
Speed
External Static Pressure (in. wg)
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
018
Low
Watts
227
212
196
177
165
153
CFM
1082
1016
929
796
668
428
—
—
—
—
—
—
—
—
—
—
Med
Watts
—
—
—
—
—
—
—
—
—
—
—
CFM
—
—
—
—
—
—
—
—
—
—
—
High
Watts
287
275
266
253
242
234
226
CFM
1270
1179
1054
932
780
633
372
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
024
Low
Watts
280
275
270
267
264
262
260
CFM
950
880
825
750
670
580
400
Med
Watts
380
375
365
360
355
350
344
335
312
—
—
CFM
1220
1150
1090
1025
970
860
760
620
450
—
—
High
Watts
485
475
470
460
455
445
437
430
415
385
—
CFM
1475
1440
1350
1275
1200
1125
1025
925
750
400
—
030
Low
Watts
280
275
270
267
264
262
260
CFM
950
880
825
750
670
580
400
Med
Watts
380
375
365
360
355
350
344
335
312
—
—
CFM
1220
1150
1090
1025
970
860
760
620
450
—
—
High
Watts
485
475
470
460
455
445
437
430
415
385
—
CFM
1475
1440
1350
1275
1200
1125
1025
925
750
400
—
036
Low
Watts
576
566
556
538
512
497
481
466
450
435
—
CFM
1430
1403
1365
1263
1157
1068
973
900
827
704
—
Med
Watts
680
671
660
624
604
620
602
558
534
512
496
CFM
1720
1630
1538
1439
1346
1267
1167
1126
1018
858
781
High
Watts
810
800
790
782
766
742
723
709
688
661
627
CFM
1800
1745
1660
1600
1547
1465
1360
1270
1163
967
876
042
Low
Watts
—
675
660
650
640
630
620
610
595
580
—
CFM
—
1454
1387
1326
1275
1204
1142
1081
995
918
—
Med
Watts
—
886
855
825
795
778
765
750
735
718
700
CFM
—
1515
1458
1406
1350
1285
1224
1163
1091
1013
932
High
Watts
—
—
—
1000
950
925
910
890
875
855
833
CFM
—
—
—
1551
1488
1424
1360
1296
1233
1148
1071
048
Low
Watts
—
727
712
700
688
666
644
622
595
569
—
CFM
—
1678
1639
1600
1561
1500
1440
1379
1289
1198
—
Med
Watts
—
853
836
821
807
782
756
730
699
667
640
CFM
—
1914
1870
1825
1780
1711
1642
1573
1470
1367
1270
High
Watts
—
979
959
943
927
897
868
838
802
766
730
CFM
—
2150
2100
2050
2000
1922
1845
1767
1600
1535
1419
060
Low
Watts
1033
949
864
836
822
808
772
737
705
674
642
CFM
2105
2057
2009
1943
1909
1876
1823
1770
1698
1627
1531
Med
Watts
1084
1054
1024
994
971
955
928
897
867
835
803
CFM
2318
2248
2179
2110
2058
2000
1932
1885
1829
1740
1638
High
Watts
—
—
1184
1152
1120
1102
1084
1056
1029
997
965
CFM
—
—
2349
2278
2207
2124
2041
2000
1960
1853
1745
*Air delivery values are without air filter and are for dry coil. (See Wet Coil Pressure Drop table.)
NOTE: Deduct field-supplied air filter pressure drop or economizer and 1-in. filter pressure drop and
wet coil pressure drop to obtain external static pressure available for ducting.
14