RECOMMENDED TUBE DIAMETERS

NOTE:

Maximum long-line tube length of 50 ft liquid and vapor line sets indicated

above must be followed on all applications. Over 50 ft, refer to Application Guide-
line and Service Manual—Air Conditioners and Heat Pumps Using Puron®
Refrigerant.

UNIT

SIZE

TUBE LENGTH

(Ft)

LIQUID TUBE

DIAMETER (In.OD)

VAPOR TUBE

DIAMETER (In.OD)

024

0 to 50

3/8

5/8

036

3/4

048

7/8

060

1-1/8

M

A

N

U

F

A

C

T

U

R

E

R

CE

RT

IFIED

TO ARI

AS

C

O

M

P

L

Y

IN

G
W

IT

H

A

RI

STANDARD

21

0

U

N

IT

A

R

Y

AIR

CO

N

D

IT

IO

N

IN

G

EQUIPMENT

CERTIFICATION APPLIES

ONLY WHEN THE

COMPLETE SYSTEM

IS LISTED WITH ARI.

As an ENERGY STAR

®

Partner, Bryant Heating and
Cooling has determined that
this product meets the
ENERGY STAR

®

guidelines

for energy efficiency.

REGISTERED QUALITY SYSTEM

CHARGING SUBCOOLING* (TXV TYPE EXPANSION DEVICE)

*Charge in high speed only.

UNIT

SIZE

HIGH

024

14

036

15

048

12

060

16