The machine does not

turn on.

The machine is not

connected to the power

supply.

Move the main switch to ON.

Check the plug and the

connection

The coffee is not hot

enough.

The cups are cold.

Warm up the cups.

The machine does not

brew coffee.

Knob positioned on too

low a setting

Turn the knob clockwise to a

higher setting.

No hot water or steam is

dispensed.

The tube nozzle is clog-

ged.

Clean the nozzle opening with

a needle.

During this operation,

the knob must be

closed and the machine

must be off.

A noise can be heard

coming from the steam

tube of the machine.

The machine takes a long

time to warm up.

Excessive scale has

built up.

Descale the machine.

The brew unit cannot be

removed.

The unit has stopped in

the wrong position.

Close the door and switch on

the machine; the brew unit will

move back into position.

PROBLEMS - CAUSES - REMEDIES

29

PROBLEMS

CAUSES

REMEDIES

Coffee fl ows out in slow

trickle or not at all.

Excessively fi ne grind

and SBS control turned

to the right.

Adjust to a coarser grind (turn

the knob clockwise).

Turn the SBS control toward

the left.