beautypg.com

Maintenance and lubrication schedule – Braun NUVL855RM24 User Manual

Page 49

background image

Page 47

Maintenance and Lubrication Schedule

Perform all procedures listed in previous section also

4500

Cycles

Inspect torque tube cams for securement, wear or
damage

Inspect housing cam brackets for securement,
wear or damage

Inspect cylinder(s), hoses, fittings and hydraulic
connections for wear, damage or leaks

Inspect power cable

Resecure, replace or correct as needed.

Resecure, replace or correct as needed.

Tighten, repair or replace if needed.

Resecure, repair or replace if needed.

1500

Cycles

Hydraulic Fluid (Pump) - Check level. Note: Fluid
should be changed if there is visible contamination.
Inspect the hydraulic system (cylinder, hoses, fit-
tings, seals, etc.) for leaks if fluid level is low.

Inspect lifting arm bushings and pivot pins for vis-
ible wear or damage

Inspect outer barrier pivot pin mounting bolts (2)

Mounting

Use 5606 aviation fluid only (part 87010R-MILL).
Check fluid level with platform lowered fully. Fill
to within 1-1/2" of the bottom of the fill tube (neck).

Replace if needed.

Tighten or replace if needed

Check to see that the lift is securely anchored to
the vehicle and there are no loose bolts, broken
welds, or stress fractures.