Page 35

Manual Operating Instructions

DOWN (Unfold Outer Barrier):

1. Remove hairpin cotter from
detent pin (see Figure D).
2. Remove detent pin.
3. Unfold (rotate) barrier down.

OUT (To Extend Platform):

1. Pull T-Handle (see Figure A).
2. Turn T-Handle to lock platform
in released position.
3. Pull platform out.
4. Turn T-Handle.
5. Push T-Handle in.
6. Turn T-Handle to lock platform
in engaged position.

DOWN (To Lower Platform):

Using hand pump handle, open
hand pump valve (turn counter-
clockwise). See Figure B. Open
1/2 turn only.

UP (To Fold Outer Barrier):

1. Fold (rotate) barrier up.
2. Insert detent pin.
3. Insert hairpin cotter in detent
pin.

UP (To Raise Platform):

Using hand pump handle:
1. Close hand pump valve (turn
clockwise).
2. Insert handle in pump and
stroke. See Figure C.

IN (To Stow Platform):

1. Raise or lower platform to
stow level (follow UP or
DOWN procedures).
2. Pull T-Handle.
3. Turn T-Handle to lock platform
in released position.
4. Push platform in.
5. Turn T-Handle.
6. Push T-Handle in.
7. Turn T-Handle to lock platform
in engaged position.

Note: Close valve before
operating electric pump.