beautypg.com

Bryant 187B User Manual

Page 12

background image

12

Thermidistat Models T6---PRH01---A & T6---NRH01---A

w/ VS Fan Coil & 2---Stage Air Conditioner

Thermidistat Model T6---PRH01---A & T6---NRH01---A

w/ VS Furnace & 2---Stage Air Conditioner

RVS/Heat Stage 2

O/W2/B

Heat Stage 1

W/W1

Compressor Low

Y1

Compressor High

Y/Y2

Fan

G

24VAC Hot Heating

Rh

24VAC Hot Cooling

Rc

Dry Contact 1

D1

Dry Contact 2

D2

24VAC Common

C

Humidify

HUM

Outdoor Air Temp

OAT

Remote Room Sensor

RRS

OAT/RRS Return

SRTN

SRTN

Outdoor Sensor

Remote Room

Sensor

O

Y1

W1

G

W2

C

Y2

Y1

Y/Y2

R

C

DH

REMOVE J2
JUMPER FOR
HEAT STAGING

REMOVE J1 FOR
DEHUMIDIFY
MODES

Two-Stage

Air Conditioner

Thermidistat

Variable Speed

Fan Coil

*

R

* See Humidifier Instructions for proper wiring.

Variable Speed

Furnace

Thermidistat

2-Stage

Air Conditioner

Heat Stage 2

O/B W2

W2

Heat Stage 1

W/W1

W1

Cool Stage 1

Y1 / W2

Y1

Cool Stage 2

Y/Y2

Y/Y2

Y/Y2

Fan

G

G

24VAC Hot Heating

Rh

R

R

24VAC Hot Cooling

Rc

Dry Contact 1

D1

Dry Contact 2

D2

DHUM

24VAC Common

C

COM

C

Humidify

HUM

Outdoor Air Temp

OAT

Remote Room Sensor

RRS

OAT/RRS Com

SRTN

Outdoor Sensor *

Remote Room

Sensor *

* See Humidifier Instructions for proper wiring

*

A09566

A09565

Fig. 10 -- Thermidistat Wiring with 2--Stage Puron refrigerant Air Conditioner

Single Stage Furnace with 2---Stage Air Conditioner

2---Stage Thermostat with Single---Stage Furnace and

2---Stage Air Conditioner

A09567

A09568

R

*

* See Humidifier Instructions for proper wiring.

R

* See Humidifier Instructions for proper wiring.

*

Fig. 11 -- VS Furnace or Fan Coil Wiring with Communicating 2--Stage AC

D

C

B

A

User Interface

D

C

B

A

D

C

B

A

Fan Coil

Communicating AC//HP

OA

T

R

Y

O

W

C

HUM*

* See Humidifier Instructions for proper wiring.

A09569

Fig. 12 -- Evolution Furnace or Fan Coil with Communicating 2--Stage AC Wiring Diagram

(See Thermostat Installation Instruction for specific unit combinations)

187B

/180B