beautypg.com

Bunn W/SMART FUNNEL S/N SNG0033000 & UP User Manual

Page 43

background image

Page 43

TROUBLESHOOTING (cont.)

Troubleshooting Procedures

Possible Cause

Screen Displayed

1. Water shut off to brewer

2. Inlet Solenoid Valve failure

3. Control Board Failure

1. Temperature Sensor Probe wire(s)

broken or not making connection.

1. Temperature Sensor Probe

wire(s) shorted to housing, or to

each other.

Check water supply shut-off

Service required

Service required

Check wire and connection of both

black and white wires of temperature

probe.

Check to confirm that wire(s) are

not pinched between two surfaces

or connected to each other.

CHECK WATER

SUPPLY

FILL TIME TOO

LONG

CHECK FOR BAD

CONNECTIONS

TEMP SENSOR

OUT OF RANGE

CHECK WIRE FOR

SHORTS

TEMP SENSOR

OUT OF RANGE

35879.1 071405