TROUBLESHOOTING SUGGESTIONS

SYMPTOM

POSSIBLE CAUSE

SUGGESTED REMEDY

Will not heat or brew
(no lights)

Brewer not plugged in or circuit
breaker tripped

Reconnect brewer to electric power
Reset circuit breaker

Fuse blown

Check satellite for water saturation
Replace fuse

Will not brew

Satellite is not in proper position Reinstall satellite. Satellite light should

be on

Brew switch damaged

Check. Replace if needed

Timer damaged

Check. Replace if needed

Volume selector switch damaged Check. Replace if needed

Satellite connector snap-action
switch damaged

Check. Replace if needed

Brewer fails to heat

Tank heat switch off

Turn tank heat switch on

Hi-limit tripped

Allow to cool, reset hi-limit

Thermostat out of adjustment or
damaged

Check. Adjust or replace as needed

Satellite receptacle or brewer
connector damaged

Check connectors. Be sure all pins are
in place and tight. Replace if needed

Brewer fails to stop
brewing after STOP

Switch not pressed long enough
or firmly enough

Switch must be pressed firmly for at
least 1 second

switch pressed

Stop Brew switch damaged

Check. Replace if needed

Brew solenoid damaged or dirty

Check. Clean or replace as needed

Coffee overflows from
brew chamber

Too much coffee or too fine a
grind

Use proper amount and grind of coffee
grounds per brew

More than 1 filter paper or wrong
type of filter paper used

Use 1 genuine Bloomfield filter paper
per brew

Timer out of adjustment or
damaged

Check time. Adjust or replace as
needed

Brew solenoid damaged

Check. Replace if needed

Wire rack missing from brew
chamber

Check. Replace if needed

Insufficient brew volume
(all volumes)

Low inlet water pressure

Other appliances on water line may be
robbing pressure. Brewer should be on
dedicated water line

Inlet strainer plugged

Clean strainer

Timers out of adjustment

Adjust time for each brew volume

Timer damaged

Check. Replace if needed

Satellite overflows
(1-1/2 gal brew only)

Bypass solenoid damaged

Check. Replace if needed

16

661 74415

9311 Sin

g

le Satelli

te Br

ew
er