Servicing instructions (continued) – Bloomfield 9311 User Manual
Page 17

SERVICING INSTRUCTIONS (continued)
15
10. Reinstall tank lid assembly into hot water tank. Make sure 
 the lid gasket is properly in place, then reinstall the hold-
 down clamps. 
 
11. Remove spray disks and gaskets. Rinse both brew heads 
 with clean water. Using a stiff brush, scrub spray disk to 
 remove any lime or calcium build-up. Reinstall gaskets 
 and spray disks. 
 
13. Reconnect brewer to electrical supply . 
 
14. Install the brew chamber without filter paper or grounds. 
 
15. Place an empty satellite under the brew chamber. Run at 
 least five 1-1/2 gallon brew cycles and discard all water 
 generated at the end of each cycle. 
 Repeat for the other side. 
 
16. Rinse satellite with clean water. Reinstall one empty 
 satellite under each brew chamber. 
 
Brewer is ready to use. 
NOTE:  Normally, silicone 
hoses do not need to be 
delimed. Should deliming 
hoses become necessary, 
Bloomfield recommends 
replacing the hoses. 
661
74415 9311 Single Satelli
te Brew
er