The coffee is not creamy on the

surface

Coffee leaks outside the brew

group

The machine takes too long to

heat up or the quantity of water

dispensed from the tube is

limited

The brew group cannot be

taken out

The blend is not suitable or the

coffee is not freshly roasted or

is ground too coarsely.

Brew group unit clogged

The machine water system is

clogged by scale

Brew group out of place

Dump box still in place

Change the coffee blend or

adjust the grinder as directed

in par.5 (Increase the dose –

Optional)

Clean the brew group and its

outlets

Descale the machine (Par. 12)

Turn on the machine. Close the

service door. The brew group

will automatically go back into

place.

Remove the dump box before

taking out the dispensing unit

Problems

Causes

Remedies