SPECIFICATIONS Continued

* Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure.

Copper wire must be used from service disconnect to unit.

† If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70).

The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70)
Article 336-26.

‡ Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2 percent.

All motors/compressors contain internal overload protection.

** Time-delay fuse.

†† Use with Low-Ambient Controller.
‡‡ Fan motor with ball bearings required.

UNIT SIZE - SERIES

042-E, F

048-E/G

060-E, F

OPERATING WT (Lb)

213

247

287

ELECTRICAL

Unit Volts—Hertz—Phase

208/230—60—1

208/230—60—1

208/230—60—1

Operating Voltage Range*

187—253

187—253

187—253

Compressor— Rated Load Amps

20.0

23.7/21.3

28.8

Locked Rotor Amps

104.0

129.0/137.0

169.0

Condenser Fan Motor—Full Load Amps

1.1

1.4

1.4

Min Unit Ampacity for Wire Sizing

26.1

31.0/28.0

37.4

Min Wire Size (60°C Copper) AWG†

10

8/10

8

Min Wire Size (75°C Copper) AWG†

10

10

8

Max Wire Length (60°C) (Ft)‡

96

71

104

Max Wire Length (75°C) (Ft)‡

91

68

99

Max Branch Circuit Fuse Size**

40

50/40

60

COMPRESSOR AND REFRIGERANT

Compressor—Manufacturer & Type

Copeland Scroll

Temperature & Current Protection

Internal Line Break

Refrigerant—R-22 Amount (Lb)

6.68

6.34

9.25

CONDENSER COIL AND FAN

Coil Face Area (Sq Ft)

15.2

18.3

Fins per In.—Rows—Circuits

25—1—3

25—1—4

Fan Motor—HP, Type, & RPM

1/5 PSC & 825

1/4 PSC & 1100

Volts—Hertz—Phase

208/230—60—1

Condenser Airflow (CFM)

3000

3300

OPTIONAL EQUIPMENT

Support Feet Kit

KSASF0101AAA

Coastal Filter

KAACF0201MED

Time-Delay Relay

KAATD0101TDR

Cycle Protector

KSACY0101AAA

Standard

Crankcase Heater

KAACH1201AAA

Start Assist—Capacitor/Relay Type

KSAHS1501AAA

KSAHS1601AAA

Start Assist—PTC Type

KAACS0201PTC

TXV Kit (RPB)

KAATX0501RPB

KAATX0601RPB

KAATX0701RPB

TXV Kits (Hard Shutoff)

KSATX0601HSO

KSATX0701HSO

Low-Pressure Switch

KAALP0101LPS

High-Pressure Switch

KSAHI0101HPS

Filter Drier

P502-8163S (RCD)

Evaporator Freeze Thermostat††

KAAFT0101AAA

Liquid-Line Solenoid Valve

KAALS0101LLS

Winter Start Control††

KAAWS0101AAA

Low-Ambient Kit

KSALA0201R22

MotorMaster® Control‡‡

32LT660004 (RCD)

Ball Bearing Fan Motor

HC38GE231 (RCD)

HC40GE232 (RCD)

Thermostat, Auto Changeover,

Non-Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool

TSTATBBNAC01-B

Thermostat, Auto Changeover,

7-Day Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool

TSTATBBPAC01-B

Builder’s Thermostat, Manual

Changeover, Non-Programmable,
°F/°C, 1-Stage Heat, 1-Stage Cool

TSTATBBBAC01-B

Thermidistat™ Control—Programmable/

Non-Programmable Thermostat with
Humidity Control

TSTATBBPRH01-B

Outdoor Air Temperature Sensor

TSTATXXSEN01-B

Backplate for Non-Programmable

Thermostat

TSTATXXNBP01

Backplate for Builder’s Thermostat

TSTATXXBBP01

Backplate for Programmable Thermostat

TSTATXXPBP01

Thermostat Conversion Kit (4 to 5 wire)

— 10 Pack

TSTATXXCNV10