23— condenser only ratings* continued – Bryant Electric 594D User Manual
Page 23

—23—
CONDENSER ONLY RATINGS* Continued
* ARI listing applies only to systems shown in Performance Data table.
KW
— Total Power (kW)
SDT
— Saturated Temperature Leaving Compressor (°F)
SST
— Saturated Temperature Entering Compressor (°F)
TCG
— Gross Cooling Capacity (1000 Btuh)
SST
°F
CONDENSER ENTERING AIR TEMPERATURES °F
55
65
75
85
95
105
115
594D042-E, F
30
TCG
39.4
37.6
35.7
33.9
32.0
30.2
28.4
SDT
77.0
86.9
96.8
107.0
117.0
127.0
137.0
KW 2.17
2.43
2.72
3.04
3.40
3.81
4.26
35
TCG
43.3
41.4
39.4
37.4
35.4
33.4
31.4
SDT
78.5
88.2
98.0
108.0
118.0
128.0
138.0
KW 2.19
2.45
2.74
3.07
3.43
3.84
4.30
40
TCG
47.5
45.4
43.3
41.1
39.0
36.8
34.6
SDT
80.0
89.7
99.5
109.0
119.0
129.0
139.0
KW 2.21
2.48
2.77
3.10
3.47
3.88
4.34
45
TCG
51.8
49.6
47.4
45.1
42.7
40.4
38.1
SDT
81.7
91.4
101.0
111.0
121.0
131.0
141.0
KW 2.24
2.51
2.80
3.14
3.51
3.92
4.39
50
TCG
56.4
54.1
51.7
49.2
46.7
44.2
41.7
SDT
83.6
93.2
103.0
113.0
122.0
132.0
142.0
KW 2.27
2.54
2.84
3.18
3.55
3.97
4.44
55
TCG
61.2
58.8
56.2
53.6
51.0
48.3
45.6
SDT
85.6
95.1
105.0
114.0
124.0
134.0
144.0
KW 2.31
2.58
2.88
3.22
3.60
4.03
4.50
594D048-E, G
30
TCG
46.0
43.8
41.6
39.3
36.9
34.4
32.0
SDT
80.1
89.8
99.6
109.0
119.0
129.0
139.0
KW 2.46
2.82
3.22
3.65
4.13
4.64
5.17
35
TCG
50.4
48.1
45.7
43.2
40.7
38.1
35.5
SDT
81.9
91.6
101.0
111.0
121.0
131.0
140.0
KW 2.49
2.85
3.25
3.69
4.18
4.71
5.25
40
TCG
55.1
52.6
50.1
47.4
44.7
41.9
39.1
SDT
83.9
93.4
103.0
113.0
123.0
132.0
142.0
KW 2.52
2.88
3.29
3.74
4.23
4.77
5.34
45
TCG
60.0
57.4
54.7
51.9
49.0
46.0
43.0
SDT
86.0
95.5
105.0
115.0
124.0
134.0
144.0
KW 2.55
2.92
3.33
3.79
4.29
4.84
5.43
50
TCG
65.2
62.4
59.6
56.6
53.5
50.3
47.1
SDT
88.3
97.7
107.0
117.0
126.0
136.0
146.0
KW 2.59
2.96
3.38
3.84
4.35
4.91
5.51
55
TCG
70.7
67.7
64.6
61.5
58.2
54.8
51.3
SDT
90.7
100.0
109.0
119.0
128.0
138.0
148.0
KW 2.64
3.01
3.43
3.90
4.42
4.98
5.60
594D060-E, F
30
TCG
55.1
52.7
50.1
47.4
44.8
42.2
39.5
SDT
80.2
89.9
99.7
109.0
119.0
129.0
139.0
KW 3.06
3.44
3.86
4.34
4.87
5.46
6.07
35
TCG
60.3
57.7
55.0
52.1
49.2
46.4
43.5
SDT
82.1
91.8
101.0
111.0
121.0
131.0
141.0
KW 3.10
3.49
3.92
4.40
4.93
5.53
6.17
40
TCG
65.7
63.0
60.1
57.1
54.0
50.9
47.8
SDT
84.1
93.7
103.0
113.0
123.0
133.0
143.0
KW 3.16
3.55
3.99
4.47
5.01
5.61
6.27
45
TCG
71.4
68.6
65.6
62.3
59.0
55.6
52.3
SDT
86.3
95.9
105.0
115.0
125.0
135.0
144.0
KW 3.21
3.62
4.06
4.55
5.09
5.69
6.36
50
TCG
77.4
74.5
71.3
67.8
64.3
60.6
57.0
SDT
88.6
98.1
108.0
117.0
127.0
136.0
146.0
KW 3.28
3.69
4.14
4.64
5.19
5.79
6.46
55
TCG
83.8
80.7
77.3
73.7
69.9
66.0
62.0
SDT
91.1
101.0
110.0
120.0
129.0
139.0
148.0
KW 3.35
3.77
4.23
4.74
5.29
5.90
6.58
SYSTEM DESIGN SUMMARY
1.
Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 in. wc.
2.
Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F (12.8°C).
3.
Maximum outdoor operating air temperature is 125°F (51.7°C).
4.
For reliable operation, unit should be level in all horizontal planes.
5.
Maximum elevation of indoor coil above or below base of outdoor unit is: Indoor coil above = 50 ft. Indoor coil below = 150 ft.
6.
For interconnecting refrigerant tube lengths greater than 50 ft or 20 ft vertical differential, consult Residential Split System Long-Line Application
Guidelines available from equipment distributor.
7.
Crankcase heater required when interconnecting refrigerant tube length exceeds 50 ft.
8.
Not more than 3 ft of refrigerant tube should be buried in the ground. If necessary to bury tubes under a sidewalk, provide a minimum 6-in. vertical
rise to the valve connections at the unit. For buried lines longer than 3 ft, consult your local distributor.
9.
Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided
10. Mismatches of indoor coil capacity more than 1 size larger than outdoor unit capacity may result in inadequate indoor comfort.
11. Do not apply capillary tube indoor coils to these units.