beautypg.com

Combination ratings continued – Bryant Electric 594D User Manual

Page 13

background image

—13—

* Tested Combination

† In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use

either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. All Bryant furnaces are equipped with TDR except for the 394HAD.

‡ Based on computer simulation. TXV must be hard shutoff type.

NOTES:

1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other

combinations are determined under DOE computer simulation procedures.

3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Minimum outdoor operating ambient in cooling mode is 55°F (12.8°C), maximum 125°F (51.7°C).

UNIT

SIZE-SERIES

INDOOR

MODEL

TOT. CAP.

BTUH

FACTORY

SUPPLIED

ENHANCE-

MENT

SEER

EERA

STANDARD

RATING

BRYANT GAS

FURNACE OR

ACCESSORY

TDR†

ACCESSORY

TXV‡

048-E, G

COILS + 355MAV060080 VARIABLE SPEED FURNACE

CC5A/CD5AA060

46,000

TDR

11.00

11.00

9.70

CC5A/CD5AW060

47,000

TDR

11.20

11.20

9.95

CD5AA048

46,000

TDR

11.00

11.00

9.60

CK3BA048

46,000

TDR

11.00

11.00

9.70

CK5A/CK5BA060

46,500

TDR

11.00

11.00

9.90

CK5A/CK5BX060

47,000

TDR

11.20

11.20

10.15

CK5A/CK5BA048

46,000

TDR

11.00

11.00

9.70

COILS + 355MAV060100 VARIABLE SPEED FURNACE

CC5A/CD5AA060

46,000

TDR

11.20

11.20

9.95

CC5A/CD5AC048

45,000

TDR

11.00

11.00

9.70

CC5A/CD5AW060

47,000

TDR

11.80

11.80

10.20

CD5AA048

46,000

TDR

11.00

11.00

9.90

CK3BA048

46,000

TDR

11.00

11.00

9.95

CK3BA060

46,500

TDR

11.20

11.20

10.15

CK5A/CK5BA048

46,000

TDR

11.00

11.00

9.95

CK5A/CK5BA060

46,000

TDR

11.20

11.20

10.40

CK5A/CK5BX060

47,000

TDR

11.80

11.80

10.40

COILS + 355MAV060120 VARIABLE SPEED FURNACE

CC5A/CD5AA060

46,000

TDR

11.20

11.20

9.95

CC5A/CD5AW048

46,000

TDR

11.20

11.20

9.90

CC5A/CD5AW060

47,000

TDR

11.80

11.80

10.25

CK3BA060

46,500

TDR

11.20

11.20

10.20

CK5A/CK5BA060

46,000

TDR

11.20

11.20

10.20

CK5A/CK5BW048

46,000

TDR

11.20

11.20

9.95

CK5A/CK5BX060

47,000

TDR

11.80

11.80

10.45

060-E

CC5A/CD5AW060*

56,500

NONE

10.80

11.00

11.00

9.70

CC5A/CD5AA060

54,500

NONE

10.60

10.80

10.80

9.55

CE3AA060

56,500

NONE

10.80

11.00

11.00

9.80

CK5A/CK5BA060

54,500

NONE

10.60

10.80

10.80

9.55

CK5A/CK5BX060

56,500

NONE

10.80

11.00

11.00

9.70

F(A,B)4(A,B)N(F,B,C)060

57,000

TDR

10.80

10.80

9.40

FB4(A,B)NB070

57,500

TDR

11.00

11.00

9.80

FC4(B,C)NB070

57,500

TDR & TXV

11.00

9.80

FC4(B,C)N(F,B)060

57,000

TDR & TXV

10.80

9.40

FG3AAA060

56,000

NONE

10.80

11.00

11.00

9.65

FK4(C,D)NB006

57,500

TDR & TXV

12.00

10.30

COILS + 315(A,J)AV066110 VARIABLE SPEED FURNACE

CC5A/CD5AA060

54,000

TDR

11

11

9.8

CE3AA060

54,000

TDR

11.2

11.2

10.1

CK3BA060

54,000

TDR

11

11

9.95

CK5A/CK5BA060

54,000

TDR

11

11

9.95

CK5A/CK5BT060

54,000

TDR

11

11

9.95

CK5A/CK5BX060

56,000

TDR

11.5

11.5

10.25

COILS + 315(A,J)AV066135 VARIABLE SPEED FURNACE

CC5A/CD5AA060

54,000

TDR

11

11

9.8

CC5A/CD5AW060

56,000

TDR

11.5

11.5

10.05

CE3AA060

54,000

TDR

11.2

11.2

10.1

CK3BA060

54,000

TDR

11

11

9.9

CK5A/CK5BA060

54,000

TDR

11

11

9.95

CK5A/CK5BT060

54,000

TDR

11

11

9.9

CK5A/CK5BX060

56,000

TDR

11.5

11.5

10.25

COILS + 315(A,J)AV066155 VARIABLE SPEED FURNACE

CC5A/CD5AA060

54,000

TDR

11

11

9.85

CC5A/CD5AW060

56,000

TDR

11.5

11.5

10.05

CE3AA060

54,000

TDR

11.2

11.2

10.15

CK3BA060

54,000

TDR

11.2

11.2

10

CK5A/CK5BA060

54,000

TDR

11.2

11.2

10

CK5A/CK5BT060

54,000

TDR

11.2

11.2

10

CK5A/CK5BX060

56,000

TDR

11.5

11.5

10.3

COMBINATION RATINGS Continued