Detailed cooling capacities* continued – Bryant 594D User Manual
Page 18
—18—
DETAILED COOLING CAPACITIES* Continued
* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI Standard 210/240-94. If additional tubing length and/or indoor
unit is located above outdoor unit, a slight variation in capacity may occur.
† Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
‡ Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh
(245 kw) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air
per degree above 80°F (27°C). When the required data falls between the published data, interpolation may be performed.
** Unit kw is total of indoor and outdoor unit kilowatts.
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F
85
95
105
115
125
CFM
EWB
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Total
Sens‡
Total
Sens‡
Total
Sens‡
Total
Sens‡
Total
Sens‡
594D060-E Outdoor Section With CC5A/CD5AW060 Indoor Section
1750
72
63.4
31.4
5.42
61.0
30.4
5.88
58.2
29.4
6.35
54.9
28.2
6.7
50.9
26.8
7.13
67
57.8
39.6
5.36
55.4
38.6
5.79
52.5
37.5
6.21
49.0
36.1
6.5
44.8
34.4
6.76
62
52.4
47.6
5.28
49.9
46.4
5.68
46.9
44.8
6.02
43.4
42.8
6.2
39.7
39.7
6.37
57
50.2
50.2
5.20
48.2
48.2
5.59
45.9
45.9
5.93
43.2
43.2
6.2
40.1
40.1
6.37
2000
72
64.7
32.8
5.44
62.1
31.8
5.91
59.3
30.8
6.38
56.0
29.7
6.8
52.1
28.3
7.22
67
59.0
42.0
5.38
56.5
41.0
5.82
53.6
39.9
6.26
50.2
38.5
6.6
46.1
37.0
6.89
62
53.6
50.7
5.31
51.1
49.4
5.72
48.3
47.6
6.10
45.1
45.1
6.3
41.9
41.9
6.59
57
52.2
52.2
5.24
50.3
50.3
5.65
48.0
48.0
6.03
45.4
45.4
6.3
42.3
42.3
6.57
2250
72
65.7
34.1
5.34
62.9
33.1
5.93
60.1
32.1
6.42
56.9
31.0
6.8
53.0
29.7
7.30
67
60.0
44.4
5.28
57.4
43.3
5.86
54.5
42.2
6.30
51.2
40.9
6.7
47.0
39.3
7.00
62
54.6
53.4
5.34
52.2
51.8
5.77
49.6
49.6
6.17
46.9
46.9
6.5
43.7
43.7
6.76
57
54.0
54.0
5.27
52.0
52.0
5.69
49.8
49.8
6.10
47.2
47.2
6.4
44.0
44.0
6.74
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Size
Cooling
Indoor
Section
Size
Cooling
Capacity
Power
Capacity
Power
CC5A/CD5AA
060
0.96
0.98
FC4BNB
070
1.02
1.02
CC5A/CD5AW
060
1.00
1.00
FC4BN(F,B)
060
1.01
1.04
CE3AA
060
1.00
1.00
FG3AAA
060
0.99
1.00
CK5A/CK5BA
060
0.96
0.98
FK4CNB
006
1.02
0.97
CK5A/CK5BX
060
1.00
1.00
COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE
F(A,B)4AN(F,B,C)
060
1.01
1.04
CC5A/CD5AW
060
1.00
0.94
FB4ANB
070
1.02
1.02
CK5A/CK5BW
060
1.00
0.94