beautypg.com

Bunn CW-APS User Manual

Page 12

background image

Page 12

TROUBLESHOOTING (cont.)

PROBLEM

Spitting or excessive steaming
(cont.)

Dripping from sprayhead

Water flows into tank continuously
(ON/OFF Switch "ON")

Water flows into tank continuously
(ON/OFF Switch "OFF")

Beverage overflows dispenser

PROBABLE CAUSE

2. Control Thermostat

1. Syphon System

2. Lime Build-up
CAUTION - Tank and tank compo-
nents should be delimed regularly
depending on local water condi-
tions. Excessive mineral build-up
on stainless steel surfaces can ini-
tiate corrosive reactions resulting
in serious leaks.

3. Solenoid Valve (CWT-APS,
CWTF-APS, CWT-TS, CWTF-TS,
CWT-TSR & CWTF-TSR)

1. Timer (CWT-APS, CWTF-APS,
CWT-TS, CWTF-TS, CWT-TSR &
CWTF-TSR)

1. Solenoid Valve (CWT-APS,
CWTF-APS, CWT-TS, CWTF-TS,
CWT-TSR & CWTF-TSR)

1. Dispenser

2. Timer (CWT-APS, CWTF-APS,
CWT-TS, CWTF-TS, CWT-TSR &
CWTF-TSR)

3. Solenoid Valve (CWT-APS,
CWTF-APS, CWT-TS, CWTF-TS,
CWT-TSR & CWTF-TSR)

REMEDY

Refer to

Service

- Control Ther-

mostat for testing procedures. See
page 16

The brewer must be level or slightly
lower in front to syphon properly.

Inspect the tank assembly for ex-
cessive lime deposits. Delime as
required.

Remove the solenoid valve and
clear any obstructions. Rebuild or
replace the valve if necessary.
See page 19

Refer to

Service -

Timer for testing

procedures. See page 25 or 27

Remove the Solenoid Valve and
clean any obstruction. Rebuild or
replace the valve if necessary. See
page 19

The dispenser must be completely
empty before starting a brew cycle.

Refer to

Service -

Timer for testing

procedures. See page 25 or 27

Remove the Solenoid Valve and
clean any obstruction. Rebuild or
replace the valve if necessary. See
page 19

10690 062300

This manual is related to the following products: