TROUBLESHOOTING (cont.)

PROBLEM

Inconsistent beverage level in dis-
penser

Consistently low beverage level in
the dispenser (CWT-APS, CWTF-
APS, CWT-TS, CWTF-TS, CWT-
TSR & CWTF-TSR)

Spitting or excessive steaming

PROBABLE CAUSE

1. Strainer /flow control (.222
GPM) (CWT-APS, CWTF-APS,
CWT-TS, CWTF-TS, CWT-TSR &
CWTF-TSR

2. Syphon System

3. Lime Build-up
CAUTION - Tank and tank compo-
nents should be delimed regularly
depending on local water condi-
tions. Excessive mineral build-up
on stainless steel surfaces can
initiate corrosive reactions result-
ing in serious leaks.

4. Water Pressure (CWT-APS,
CWTF-APS, CWT-TS, CWTF-TS,
CWT-TSR & CWTF-TSR)

1. Timer

2. Strainer/flow Control (.222
GPM)

1. Lime Build-up
CAUTION - Tank and tank compo-
nents should be delimed regularly
depending on local water condi-
tions. Excessive mineral build-up
on stainless steel surfaces can
initiate corrosive reactions result-
ing in serious leaks.

REMEDY

(A) Direction of flow arrow must
be pointing towards the brewer.

(B) Remove the strainer/flow con-
trol and check for obstruction.
Clear or replace.

The brewer must be level or slightly
lower in front to syphon properly.

Inspect the tank assembly for ex-
cessive lime deposits. Delime as
required.

The water pressure to the brewer
must be at least 20 psi (138 kPa).

Timer must activate solenoid for
at least two minutes and fifteen
seconds.

(A) Direction of flow arrow must
be pointing towards brewer.

(B) Remove the strainer/flow con-
trol and check for obstructions.
Clear or replace.

Inspect tank assembly for exces-
sive lime deposits. Delime as re-
quired.