TROUBLESHOOTING (cont.)

PROBLEM

Brew cycle will not start (cont.)
(CWT-APS, CWTF-APS, CWT-TS,
CWTF-TS, CWT-TSR &CWTF-
TSR)

Water is not hot

PROBABLE CAUSE

REMEDY

3. ON/OFF Switch

4. Start Switch

5. Timer

6. Solenoid Valve

7. Water strainer/flow control
(.222 GPM)

1. Tank Heater Switch

2. Limit Thermostat
CAUTION - Do not eliminate or
bypass limit thermostat. Use only
BOM replacement part
#29329.1000

3. Control Thermostat

4. Tank Heater

Refer to

Service

- ON/OFF Switch

for testing. See page 18

Refer to

Service

- Start Switch for

testing procedures. See page 20

Refer to

Service

- Timer for testing

procedures. See page 25 or 27

Refer to

Service

- Solenoid Valve

for testing procedures. See page
19

(A) Direction of flow arrow must
be pointing towards brewer.

(B) Remove the strainer/flow con-
trol and check for obstructions.
Clear or replace.

Refer to

Service

- Tank Heater

Switch for testing procedures. See
page 23

Refer to

Service

- Limit Thermo-

stat for testing procedures. See
page 17

Refer to

Service

- Control Ther-

mostat for testing procedures. See
page 16

Refer to

Service

- Tank Heater for

testing procedures. See page 21