General specifications, Data transmission ranges – Brocade Communications Systems Extension Switch 7800 User Manual
Page 44

32
Brocade 7800 Extension Switch Hardware Reference Manual
53-1001350-04
General specifications
A
ATTENTION
Never use the power cord packed with your equipment for other products.
General specifications
lists the general specifications for the Brocade 7800.
Data transmission ranges
provides the data transmission ranges for different cable types and port speeds for Fibre
Channel. Up to 500km at 1G is supported when using a long distance transport system such as
DWDM.
provides the data transmission ranges for different optical cable types and port speeds
for GbE SFP ports.
provides the data transmission ranges for different cable types and port speeds for
copper-cabled GbE SFP ports and the fixed copper GbE RJ-45 ports.
TABLE 10
General specifications
Specification
Description
Configurable port types
The GbE ports can be VE_Ports.
The Fibre Channel ports can be E_Ports, EX_Ports, FL_Ports, or
F_Ports.
System architecture
Nonblocking shared-memory Extension Switch
System processors
PowerPC 440EPx, 667 MHz CPU
GoldenEye2 switch ASIC
Cavium CN5470 750 MHz processor
Blaster FPGA
ANSI Fibre Channel protocol
FC-PH (Fibre Channel Physical and Signalling Interface standard)
Modes of operation
Fibre Channel Class 2 and Class 3
Fabric initialization
Complies with FC-SW-3 Rev. 6.6
FCIP (IP over Fibre Channel)
Complies with FC-IP 2.3 of FCA profile
Aggregate Extension Switch I/O
bandwidth
A total 268 Gbps:
•
256 Gbps if all 16 FC ports are running at 8 Gbps, full duplex
•
12 Gbps if all 6 GbE ports are running at 1 Gbps, full duplex
Port-to-port latency
Less than 2 microseconds with no contention (destination port is
free)
Link cost
The sum of all established/low metric (or currently active) circuits’
MAX rates in the tunnel.