Leds on the nonport side of the brocade 7800 – Brocade Communications Systems Extension Switch 7800 User Manual
Page 38

26
Brocade 7800 Extension Switch Hardware Reference Manual
53-1001350-04
Operating the Brocade 7800 Extension Switch
3
LEDs on the nonport side of the Brocade 7800
The nonport side of the Brocade 7800 has the following LEDs:
•
One power supply LED next to the AC power switch on each fan and power supply
assembly. See
on page 5 for a diagram of the non-port side of the switch.
describes the LEDs on the nonport side of the Extension Switch.
TABLE 5
Nonport Side LED patterns during normal operation
LED Name
LED Color
Status of Hardware
Recommended Action
Power Supply/
Fan Status
No light
Power supply is not seated correctly. Verify that the power supply is
seated correctly.
Steady green
System is on and power supplies are
functioning properly.
No action required.
Flashing green
Fault has occurred in the FRU.
Try the following:
•
Check the power cable
connection.
•
Verify that the power supply is
powered on.
•
Run psShow and fanShow
commands to determine the
source of the fault.
•
Replace the FRU.