4 wordclock connection, Operating software, Specifications – Behringer high-precision digital 24-bit/96 kHz EQ/RTA mastering processor DEQ2496 User Manual
Page 18: Operating software 7. specifications

18
ULTRACURVE PRO DEQ2496 User Manual
5.4 WORDCLOCK connection
If several devices shall be embedded into a digital recording system comprising,
for example, a digital mixing console, all connected digital devices must be
synchronized using a common wordclock signal. To this end, your DEQ2496
features a wordclock input, which can be used to control external equipment via
wordclock signals. The input supports the sample rates 44.1, 48, 88.2 and 96 kHz,
and can be activated only if the analog inputs are used.
6. Operating Software
The operating software of your ULTRACURVE PRO DEQ2496 is constantly being
developed to improve its performance and adapt the operation of the unit to user
requirements. We would therefore be pleased to hear about your suggestions
and ideas for improvement. We will try to include your suggestions in the next
software revision. Information on new software versions are available from the
trade press, your retailer, from our web site at behringer.com or directly from
BEHRINGER (Tel. +49 2154 9206 4166).
The current software revision of your ULTRACURVE PRO DEQ2496 is displayed in
the UTILITY menu on page 1 (top right).
7. Specifications
Analog Inputs
Type
electronically balanced
Connector XLR
Impedance
22 kΩ at 1 kHz
Max. input level
+12 or +22 dBu, switchable
CMRR
40 dB typ.
Analog Outputs (Main)
Type servo-balanced
Connector XLR
Impedance
100 Ω at 1 kHz
Max. output level
+12 or +22 dBu, switchable
Analog Outputs (Aux)
Type servo-balanced
Connector
1/4" stereo jack
Impedance
100 Ω at 1 kHz
Max. output level
+12 dBu
System Specifications
Frequency range
10 Hz to 35 kHz (-1 dB)
@ 96 kHz sampling rate
Signal-to-noise ratio
> 113 dB main input/output
> 107 dB aux output
THD
0.007 % typ. @ +4 dBu, 1 kHz, unity
gain
Crosstalk
< -92 dB/-95 dB
Bypass
Type
Relay, hard-bypass in case of power
failure
Measurement Microphone Input
Type
electronically balanced
Input impedance
2 kΩ
Max. input level (LINE)
variable from -14 dBu to +22 dBu
Max. input level (MIC)
variable from -42 dBV/Pa to -6 dBV/Pa
Phantom power
+15 V, switchable
Digital Input 1
Type
XLR transformer-balanced
Standard
AES/EBU or S/PDIF
Input impedance
110 Ω
Nom. input level
0.2 - 5 V peak-to-peak