Caution – Bloomfield 8572 User Manual
Page 13

SERVICING INSTRUCTIONS
ACCESS PANELS 
 
Each warmer plate has a center stud which screws into a 
bracket. Warmer plates on Canadian brewers are secured with 
a nut. Remove button plug on bottom of brewer to access nut 
on warmer plate. Remove warmer plates by turning counter-
clockwise. 
Solenoid door is held by two screws and a retaining lip. 
 
Front Panel (In-Line Models) and Top / Rear Panel (3-Station 
Models): 
 
a. Remove warmer plate by turning counter-clockwise
until it unscrews.
b. Remove screws from two retaining clips under
warmer plate.
c. Lift off panel.
 
Front Panel (3-Station Models): 
 
a. Remove warmer plates by turning counter-clockwise
until they unscrew.
b. Remove screws from two retaining clips under each
warmer plate.
c. Remove three screws from bottom-side of front lip.
d. Pull bottom of panel forward until it clears.
 
Top Panel (All Models): 
 
a. Remove two screws from rear of top panel.
b. Lift rear of panel, remove to rear.
CAUTION:
SHOCK HAZARD
Opening access panels or 
removing warmer plates on this 
brew may expose uninsulated 
electrical components. 
Disconnect brewer from 
electrical power before 
removing any panel or warmer 
plate. 
Fig. 9 Access Panels
11
M
611 75804
Owne
rs M
anual
Koffee-K
ing™ B
rewers