Alcove installation and clearances – New Buck Corporation 261 User Manual
Page 37
NOTE: All clearances are to combustibles with all low clearance shields and double wall
pipe , and minimum floor protector.NOTE: Floor protector must extend length of
horizontal flue pipe to wall. NOTE: Model 261 comes standard with low clearance shields.
BACK WALL
SIDE WAL
L
A
E
B
F
D
G
Figure 29
IN
SIDE
WALL
Figure 30.
CEILING
WALL
PASS-THROUGH
CONNECTOR
LISTED 2100° UL 103 HT TYP. CHIMNEY
REEFER TO MANUFACTURERS
INSTALLATION INSTRUCTION
LISTED 2100° UL 103 HT TYP.
CHIMNEY T-BOX ASSEMBLY
REEFER TO MANUFACTURERS
INSTALLATION INSTRUCTION
DVL CLOSE
CLEARANCE
A B C
D E F G H I
MODEL 261 14" 4" 7" 16" 8" 3 47" 10" 84"
D
D
B
G
A
E
Maintain Manufactures Minim Clearances
CENTER LINE
OF ELBOW
MARK PLUMB
LINE ON WALL
NEW BUCK CORP.
CAST COLLAR
Part# MA6CHIMCNB
SIDE WALL
BACK WALL
I
C
BUCK STOVE
Maintain
Manufacturers
Minimum Clearances
D
PROTE
C
TO
R
F
C
H
NOTE:
ALCOVE INSTALLATION
AND CLEARANCES
A-2. Alcove Vertical Wall exit using (6" DVL Close Clearance pipe, Elbow
and any listed 2100° UL 103 HT. TYPE Chimney).
With standard close clearance shield and pipe shield.
Model 261 minimum clearance to combustibles.
35