TABLE 7.1: SUMMARY OF HORIZONTAL VENTING OPTIONS

VENT OPTION #

1

2

3

4

CLASSIFICATION USED IN THIS
MANUAL

HORIZONTAL
CONCENTRIC

HORIZONTAL

TWIN PIPE

(RESERVED

FOR FUTURE

USE)

(RESERVED FOR

FUTURE USE)

ILLUSTRATED IN FIGURE

7.2

7.3

VENT PIPE STRUCTURE
PENETRATION

WALL

WALL

AIR INTAKE PIPE STRUCTURE
PENETRATION

WALL

WALL

VENT PIPE SIZE

60/100 mm

CONCENTRIC

3”

AIR INTAKE PIPE SIZE

3”

MAXIMUM

LENGTH

VENT

FCM090

FCM120

18ft

55ft

INLET

FCM090

FCM120

18ft

55ft

MINIMUM

LENGTH

VENT

FCM090

FCM120

10in

2ft

INLET

FCM090

FCM120

10in

2ft

VENT TERMINAL

60/100 mm

CONCENTRIC

P/N 8110701

AIR INTAKE TERMINAL

3” 90 ELBOW

VENT MATERIAL

U.S. Boiler

60/100mm

VENT

COMPONENTS

SHOWN IN

TABLE 7.4

APPROVED

STAINLESS

STEEL VENT

SYSTEM

SHOWN IN

TABLE 7.5

AIR INTAKE MATERIAL

GALVANIZED

OR PVC