7000W Generator

8

USING THE GENERATOR

System Ground

The generator has a system ground that connects the
generator frame components to the ground terminals on
the AC output receptacles.The system ground is connected
to the AC neutral wire (the neutral is bonded to the
generator frame).

Special Requirements

There may be Federal or State Occupational Safety and
Health Administration (OSHA) regulations, local codes, or
ordinances that apply to the intended use of the generator.
Please consult a qualified electrician, electrical inspector, or
the local agency having jurisdiction.

• In some areas, generators are required to be registered

with local utility companies.

• If the generator is used at a construction site, there may

be additional regulations which must be observed.

Connecting to a Building’s Electrical

System

Connections for standby power to a building’s electrical
system must be made by a qualified electrician.The
connection must isolate the generator power from utility
power, and must comply with all applicable laws and
electrical codes.

OPERATING THE

GENERATOR

IMPORTANT: Always unplug the battery float charger
before starting the generator.

Starting the Engine

Disconnect all electrical loads from the generator. Follow
start instruction steps in numerical order:

1.

Make sure unit is on a level surface.

IMPORTANT: Failure to start and operate unit on a level
surface will cause the unit not to start or shut down during
operation.

2.

Follow start instructions given in engine owner’s manual
and turn start switch on generator to “Start” position
(Figure 3).

To prolong the life of starter components, DO NOT
hold starter switch in “Start” position for more than
15 seconds, and pause for 1 minute.

NOTE: If engine starts but fails to run, or if unit shuts down
during operation, make sure unit is on a level surface and
check for proper oil level in crankcase.This unit may be
equipped with a low oil protection device. See engine manual.

• See “Don’t Overload Generator” on page 13.

• Start generator and let engine stabilize before connecting

electrical loads.

• Connect electrical loads in OFF position, then turn ON for

operation.

• Turn electrical loads OFF and disconnect from generator

before stopping generator.

Exceeding generators wattage/amperage capacity can
damage generator and/or electrical devices connected
to it.

CAUTION

Figure 3 — Starter Switch

• When using generator for backup power, notify utility

company. Use approved transfer equipment to isolate
generator from electric utility.

• Use a ground fault circuit interrupter (GFCI) in any damp or

highly conductive area, such as metal decking or steel work.

• DO NOT touch bare wires or receptacles.
• DO NOT use generator with electrical cords which are worn,

frayed, bare or otherwise damaged.

• DO NOT operate generator in the rain.
• DO NOT handle generator or electrical cords while standing

in water, while barefoot, or while hands or feet are wet.

• DO NOT allow unqualified persons or children to operate or

service generator.

Generator produces powerful voltage.
Failure to isolate generator from power utility
can result in death or injury to electric utility
workers due to backfeed of electrical energy.

DANGER