OPERATION (continued)
7
WATER HEATER
Water temperature is sensed by a 
thermobulb inserted into the water tank. This 
temperature signal is fed to the thermostat, 
which controls line power to the heating 
element. 
The setpoint temperature is adjustable at the 
thermostat. 
The element is protected from over-
temperature by a hi-limit thermostat. 
 
 
 
 
WATER FLOW
 
POUR-OVER FEATURE 
Pouring any amount of cold water into the 
pour-over opening and into the basin pan 
forces an identical amount of hot water out 
of the tank and through the spray head into 
the brew chamber. 
 
AUTOMATIC OPERATION
Pressing BREW button energizes the 
solenoid valve, allowing water from an 
external water supply to flow into the basin 
pan and then into the hot water tank. This 
forces an identical amount of hot water out 
of the tank and through the spray head into 
the brew chamber 
The solenoid uses a flow control device so 
that flow is consistent between 20 p.s.i. and 
90 p.s.i. 
Length of time the solenoid is open is 
controlled by the timer. 
 
HOT WATER FAUCET
The faucet water coil is submerged in the hot 
water tank and draws heat from the brew 
water. Water going to the water coil is not 
controlled by the solenoid valve. 
The faucet is at supply water pressure any 
time the faucet shut-off valve is OPEN. 
Fig. 6 Water Flow Diagram
Fig. 5 Heat Control Diagram