10. Adjust attack (Atime) and release (Rtime) to your preferred values.

11. Press the SELECT encoder when finished to return to the top-level DEQ screen.

DELAY
The DELAY DSP module digitally slows the final signal output from the amplifier by a

programmable amount (expressed as either distance or time). This signal delay helps

prevent phase and synchronization problems caused by sound traveling through air

over long distances, e.g., between speaker arrays separated by long distances or

between a performance stage and distant sound reinforcement speakers.

Programming signal delay
1. Choose between signal paths (A#1, B#1) by rotating the SELECT encoder knob.
2. Press the SELECT encoder knob to enter the parameter screens.
3. Move up or down between parameters by pressing the UP / DOWN arrow buttons.
4. Choose between 0° and 180° phase (PHASE) by rotating the SELECT encoder knob.

5. Choose your amount of signal delay (Delay) by rotating the SELECT encoder button.
6. Fine tune the Delay value using the (fine) parameter.

7. Change the delay’s unit of measure (Unit), if necessary, by rotating the

SELECT encoder knob. The delay value can be expressed in milliseconds (ms),

meters (m), or feet (ft).

8. Press the SELECT encoder when finished to return to the top-level DELAY screen.

LIMIT
The LIMIT DSP module controls the unit’s output limiter, with programmable

parameters for threshold (Thresh), release (Rtime), and hold (Hold).
The top-level LIMIT screen always displays the threshold (Thresh) setting for

quick reference.

Programming the output limiter
1. Choose between signal paths (A#1, B#1) by rotating the SELECT encoder knob.
2. Press the SELECT encoder knob to enter the parameter screens.
3. Move up or down between parameters by pressing the UP / DOWN

arrow buttons.

4. Choose a threshold (Thres) setting by rotating the SELECT encoder knob.
5. Choose a release time (Rtime) by rotating the SELECT encoder knob.
6. Choose a hold (Hold) setting by rotating the SELECT encoder knob.
7. Press the SELECT encoder when finished to return to the top-level LIMIT screen.

3.3 BEHRINGER Amp Remote Software

The BEHRINGER Amp Remote software allows the user to control all iNUKE DSP

settings remotely from a computer via the USB connection located on the iNUKE

front panel.

3.3.1 METERS

Meters
Monitor input and output levels by using the virtual meters on the right hand

side of the control software screen. Adjust input levels using the knobs on the

amplifier’s front panel.

The Amp Remote software displays two level meters, one for the input signal,

and another meter for the final output signal.

Input Meters

The input meters show the signal level at the CH A and CH B inputs. If the input

signal exceeds the 0 dB level, the red Clip indicator will light over the channel

experiencing an overload.
The input level can only be controlled by using the CH A and CH B knobs on the

front panel of the iNUKE amplifier. The Amp Remote software does not control

the input level.