beautypg.com

Maintenance and lubrication schedule – Braun NL955 User Manual

Page 51

background image

Maintenance and Lubrication Schedule

Resecure, replace or correct as needed.

Use Braun 32840-QT (Exxon

®

Univis HVI 26)

hydraulic fluid (do not mix with Dextron III or other
hydraulic fluids). Check fluid level with platform
lowered fully
and roll stop unfolded fully. Fill
to within 1/2˝ of the bottom of the 1-1/2˝ fill tube
(neck).

Tighten, repair or replace if needed.

Tighten, repair or replace if needed.

Inspect cotter pins on platform pivot pin (2).

Hydraulic Fluid (Pump) - Check level. Note: Fluid
should be changed if there is visible contamination.
Inspect the hydraulic system (cylinder, hoses, fit-
tings, seals, etc.) for leaks if fluid level is low.

Inspect cylinders, fittings and hydraulic connections
for wear, damage or leaks.

Inspect outer barrier cylinder hose assembly (hose,
fasteners, connections, etc.) for wear, damage or
leakage.

4500

Cycles

Perform all procedures listed in previous sections also

1500

Cycles

Resecure, replace or correct as needed.

Remove pump module cover and inspect:
• Hydraulic hoses, fittings and connections for

wear or leaks.

• Harness cables, wires, terminals and connec-

tions for securement or damage.

• Control board, circuit breaker, power switch and

lights for securement or damage.

continued

Page 49