2011AS3297 Manual

5

B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350

PH (815) 433-5100 -- FAX (815) 434-7094

4.0 INSTALLATION

The Model 2011 is designed to be used

in pairs, with one unit installed

between an asynchronous DTE and a synchronous DCE on either end of a
synchronous communication link. Figure 3 illustrates a typical Model 2011
installation.

Figure 3. Typical Model 2011 application

4.1 CONNECTING THE ASYNCHRONOUS PORT

The asynchronous port of the Model 2011 is a DB-25 female and is

configured as "DCE". Therefore it wants to talk to a DTE device such as a
terminal or PC. The Model 2011 may be plugged directly into the DB-25
serial port of a DTE or connected via "straight through" cable.

4.2 CONNECTING THE SYNCHRONOUS PORT

The synchronous port of the Model 2011 is a DB-25 male and is

configured as "DTE". Therefore it wants to talk to a DCE device such as a
modem or multiplexer. The Model 2011 may be plugged directly into the
DB-25 serial port of a DCE or connected via "straight through" cable.