8
2011AS3297 Manual
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350
PH (815) 433-5100 -- FAX (815) 434-7094
APPENDIX C: SYNCHRONOUS PORT
CONNECTIONS (CONFIGURED AS “DTE”)
Pin
Name
Description
1
FG
Frame Ground; connected straight to asynchronous
port
2
TXD
Transmit Data (from 2011); data output to synchronous port
3
RXD
Receive Data (to 2011); data input from the synchronous
port input to 2011 power supply
4
RTS
Request to Send (from 2011); 4 bit delay from
asynchronous port (2011 waits 4 bits before dropping RTS
to the synchronous port; this facilitates use in a polling
environment)
5
CTS
Clear to Send (to 2011); connected straight through to
asynchronous port
6
DSR
Data Set Ready (to 2011); connected straight through to
asynchronous port
7
SG
Signal Ground; connected straight through to
asynchronous port
8
CD
Carrier Detect (to 2011); connected straight through to
asynchronous port
9
+DCV
Connected straight through to asynchronous port
10
–DCV
Connected straight through to asynchronous port
15
TXC
Transmit clock (to 2011); used to synchronize data
conversion from 2011 to synchronous port
17
RXC
Receive clock (to 2011); used to synchronize data
conversion from 2011 to synchronous port
20
DTR
Data Terminal Ready (from 2011); input to power supply
22
Rl
Ring Indicator (to 2011); connected straight through to
asynchronous port