Location requirements – Whirlpool WED7500VW User Manual
Page 9
9
DRYER DIMENSIONS
23
3
/
8
"
(594 mm)
33
1
/
4
"
(845 mm)
23
1
/
4
"
(603 mm)
39"
(991 mm)
Back view:
NOTE: Most
installations require a
minimum of 3" (76 mm)
clearance behind dryer
for exhaust vent with
elbow. See “Venting
Requirements.”
LOCATION REQUIREMENTS
Check code requirements. Some codes limit, or do not permit,
installing dryer in garages, closets, mobile homes, or sleeping
quarters. Contact your local building inspector.
You will need:
n
A location allowing for proper exhaust installation.
See “Venting Requirements.”
n
A separate 30 amp circuit.
n
If using power supply cord, a grounded electrical outlet
located within 2 ft. (610 mm) of either side of dryer.
See “Electrical Requirements.”
n
Floor must support dryer weight of 200 lbs. (90.7 kg).
Also consider weight of companion appliance.
n
Level floor with maximum slope of 1" (25 mm) under entire
dryer.
n
For garage installation, place dryer at least 18" (460 mm)
above floor. If using a pedestal, you will need 18" (460 mm)
to bottom of dryer.
n
The dryer must not be installed or stored in an area where
it will be exposed to water and/or weather.
IMPORTANT: Do not operate, install, or store dryer where
it will be exposed to water, weather, or at temperatures below
45° F (7° C). Lower temperatures may cause dryer not to
shut off at end of sensor cycles, resulting in longer drying times.
Installation Clearances
Space must be large enough to allow door to fully open.
Side view:
Front view:
3
1
/
4
"
(83 mm)
11
3
/
4
"
(299 mm)
27"
(686 mm)
Power supply
cord/cable
Vent