Cavity depth

A cavity depth of 560 mm is

recommended for the appliance. If the

cavity depth is smaller – at least

550 mm – the energy consumption

increases slightly.

Installation location

Install the appliance in a dry, well

ventilated room. The installation location

should neither be exposed to direct

sunlight nor near a heat source, e. g.

a cooker, radiator, etc. If installation next

to a heat source is unavoidable, use

a suitable insulating plate or observe

the following minimum distances to a

heat source:

3 cm to electric or gas cookers.

30 cm to an oil or coal-fired cooker.

Connecting the

appliance

After installing the appliance, wait at least

1 hour until the appliance is switched on.

During transportation the oil in the

compressor may have flowed into the

refrigeration system.
Before switching on the appliance for the

first time, clean the interior of the

appliance (see chapter “Cleaning the

appliance”).

Electrical connection

The socket must be near the appliance

and also freely accessible following

installation of the appliance.
The appliance complies with the

protection class I. Connect the appliance

to 220–240 V/50 Hz alternating current

via a correctly installed socket with

protective conductor. The socket must

be fused with a 10 to 16 A fuse.
For appliances operated in non-

European countries, check whether the

stated voltage and current type match

the values of your mains supply. This

information can be found on the rating

plate. Fig. 0

m

Warning

Never connect the appliance

to electronic energy saver plugs.
Our appliances can be used with mains

and sine-controlled inverters. Mains-

controlled inverters are used

for photovoltaic systems which

are connected directly to the national

grid. Sine-controlled inverters must be

used for isolated applications (e.g. on

ships or in mountain lodges) which are

not connected directly to the national

grid.