Room temperature,

ventilation

and cavity depth

Ambient temperature

The appliance is designed for a specific

climate class. Depending on the climate

class, the appliance can be operated at

the following temperatures.
The climate class can be found on

the rating plate. Fig. /

Note
The appliance is fully functional within

the room temperature limits of the

indicated climatic class. If an appliance

of climatic class SN is operated at

colder room temperatures, the appliance

will not be damaged up to a temperature

of +5 °C.

Ventilation

The air on the rear panel of the appliance

heats up. Conduction of the heated air

must not be obstructed.

Otherwise, the refrigeration unit must

work harder. This increases power

consumption. Therefore: Never cover

or block the ventilation openings!

Cavity depth

A cavity depth of 560 mm is

recommended for the appliance.

If the cavity depth is smaller –

at least 550 mm – the energy

consumption increases slightly.

Installation location

Install the appliance in a dry, well

ventilated room. The installation location

should neither be exposed to direct

sunlight nor near a heat source,

e. g. a cooker, radiator, etc. If installation

next to a heat source is unavoidable,

use a suitable insulating plate or observe

the following minimum distances to a

heat source:

3 cm to electric or gas cookers.

30 cm to an oil or coal-fired cooker.

Connecting

the appliance

After installing the appliance, wait at least

1 hour until the appliance is switched on.

During transportation the oil in

the compressor may have flowed into

the refrigeration system.
Before switching on the appliance for

the first time, clean the interior of

the appliance (see chapter “Cleaning

the appliance”).

Electrical connection

The socket must be near the appliance

and also freely accessible following

installation of the appliance.
The appliance complies with the

protection class I. Connect the appliance

to 220–240 V/50 Hz alternating

current via a correctly installed socket

with protective conductor. The socket

must be fused with a 10 to 16 A fuse.

Climate class Permitted ambient temperature
SN

+10 °C to 32 °C

N

+16 °C to 32 °C

ST

+16 °C to 38 °C

T

+16 °C to 43 °C