Step 2: Connect to gas supply
1. The inlet to the appliance is ISO 7

- Rp

1

2

” internal thread situated

towards the top right corner of
the rear.

2. Fit the bayonet connection to the

wall in the shaded area as shown.
The

shaded

area

shown

is

applicable to installations in
minimum depth cabinets.
If more room is available, the
bayonet fixing area can be
extended,

provided

that

the

flexible tube does not obscure the
fan intake.

3. Use a 900mm - 1125mm length of

flexible connector.

The flexible

connector shall be fitted such that
it cannot come into contact with a
moveable part of the housing unit
(eg; drawer) and does not pass
through any space susceptible of
becoming congested. Make sure
that the flexible connector does not
block the cooling fan inlet.

4. Flexible connections should be to

BS669.

Parts of the appliance

likely to come into contact with
a flexible connecter have a
temperature rise less than 70˚C.

5. Rigid connections must be accessible

to disconnect for servicing. Cut a
150mm square hole in the right
hand rear corner of the support
shelf for the supply pipe.

6. Make sure all connections

are gas sound.

Important: - ensure that you route
all mains and electrical cables and
flexible tubing well clear of any
adjacent heat source.