TROUBLESHOOTING (cont.)

PROBLEM

Brew cycle will not start (cont.)
(CWT-APS, CWTF-APS, CWT-TS,
CWTF-TS)

Water is not hot

PROBABLE CAUSE

REMEDY

5. Timer

6. Solenoid Valve

7. Water strainer/flow control
(.222 GPM)

1. Tank Heater Switch

2. Limit Thermostat
CAUTION - Do not eliminate or
bypass limit thermostat. Use
only BOM replacement part
#04680.0000

3. Control Thermostat

4. Tank Heater

Refer to

Service

- Timer for

testing procedures. See page 22

Refer to

Service

- Solenoid Valve

for testing procedures. See page
18

(A) Direction of flow arrow must
be pointing towards brewer.

(B) Remove the strainer/flow
control and check for obstruc-
tions. Clear or replace.

Refer to

Service

- Tank Heater

Switch for testing procedures.
See page 21

Refer to

Service

- Limit Thermo-

stat for testing procedures. See
page 16

Refer to

Service

- Control

Thermostat for testing
procedures. See page 15

Refer to

Service

- Tank Heater

for testing procedures. See page
19