Appliance details

9

construction, infiltration air is normally adequate to
provide air for combustion.

• Appliances located in confined spaces:

The confined space must be provided with two
permanent openings, one commencing within 12
inches (304.8mm) of the top and one commencing
within 12 inches (304.8mm) of the bottom of the
enclosure. Each opening must have a minimum free
area of one square inch per:
– 1000 Btu/hr (292.81 Watts) if all air is taken from

inside the building

– 2000 Btu/hr (585.62 Watts) if all air is taken from

the outside by horizontal ducts

– 4000 Btu/hr (1171.24 Watts)if all air is taken from

the outside by direct openings or vertical ducts

Or the confined space must be provided with one
permanent opening or duct that is within 12 inches
(304.8mm) of the ceiling of the enclosure. This opening
must have a minimum free area of one square inch per:

– 3000 Btu/hr (878.43 Watts) if all air is taken from

the outside by a direct opening or vertical duct.

Louvers, grills and screens have a blocking effect, when
used, increase the sizes of your openings by 300% for
wood louvers (as wood type will reduce the free air by
75%) and 40% for metal louvers (as metal will reduce
the free air by 30%). Refer to the National Fuel Gas
Code for complete information. In buildings of tight
construction all air should be taken from outside.
NOTE: It is not recommended to use interior
room air (SINGLE PIPE vent system) in areas that
commonly experience below freezing
temperatures. Clothes dryers, furnaces,
woodstoves, bathroom or kitchen fans or other
gas appliances can create negative air pressure
when operating by removing air from the
building. Cold air will be drawn back into the
building, and if drawn through the water heater a
freezing situation may occur. TWIN PIPE (room
sealed) method of venting is recommended, see
page
12.
NOTE: When installed in beauty shops, barber
shops, or other facilities where chemicals that
generate corrosive or flammable products such
as aerosol sprays are routinely used, shall be
installed as sealed unit following the TWIN PIPE
SYSTEM method of venting.

2.9

Venting

NOTE: This appliance's exhaust must be vented
to the outside with sealed stainless steel vent
pipe (AL29-4C), the minimum vent length is 3 feet
(a 90 degree vent elbow is equivalent to 2 ½ feet).
The appliance's flue gasses are under positive
pressure and must travel through a stainless
steel 3" or 4" pipe that is sealed gas tight.
NOTE: The exhaust collar on the water heater is
3" diameter and its collar must always be used, a
3" to 4" increaser will be required to be first
connected to the exhaust collar when 4" venting
is used. Different stainless steel vent
manufacturer's have different joint systems, do
not mix vent pipe or joining methods from
different manufacturer's.
Stainless steel vent pipe is equipped with sealing
gaskets for ease of installation, proper safety
and durability. The heater shall not be vented in
combination with any other appliance; the
appliance must only be vented with a dedicated
sealed vent system.

Establish vent clearances that comply with the vent
manufacturer's specifications. In all cases follow local
codes. See table 3.

Warning: Do not reduce the vent
(exhaust and combustion) pipe sizes
and do not common vent with any other
vented appliance or stove.

Z flex

Protech

Heat Fab

BBTNA

3” VENTING

3” Horizontal

Terminal

2SVSTB03

FSTB3

9390 TEE

2SVSTB03

3” Vertical

terminal

2SVSRCF03

FSRC3

5300CI

2SVSRCF03

4” VENTING

Requires a 3”

to 4” Increaser

2SVI0304

FS0304TI

9374

2SVI0304

4” Horizontal

terminal

2SVSRTF04

FSTB4

9490TEE

FXHOOD

4” Vertical

terminal

2SVSRCF04

FSRC4

5400CI

----------

Table 2 Terminals/Adapters Part Numbers

Caution: The vent system must be
installed by a qualified agency in
accordance with these instructions. If
improperly installed a hazardous
condition such as explosion or Carbon
Monoxide poisoning could result.
BBTNA will not be responsible for
improperly installed appliances.