beautypg.com

9special adjustment for measuring and adjusting co, Levels – Bosch 2400E NG User Manual

Page 32

background image

6 720 608 263

32

Special adjustment for measuring and adjusting CO2 levels

9

Special adjustment for measuring and adjusting CO

2

levels

The CO

2

can only be adjusted by a certified gas

technician with a calibrated CO

2

analyzer.

Static Gas Pressure:

“ WC

P1 Operating Pressure:

“ WC

The P1 minimum operating pressure is 5" WC for
Natural Gas and 11"WC for Propane. Do not proceed
in adjusting CO

2

until pressure has been verified to be

at or above these levels, but not to exceed 14” WC.

A. Once Pressure is good

B Turn ON/OFF switch to the OFF (O) position.

B Remove brass flat head screw on the exhaust collar

as seen in Fig. 42.

B Insert CO2 analyzer probe into the measuring port.

The tip of the probe should be in the center of the flue
pipe (approx 1.5" inserted).

Fig. 42