On / off, Cv-p10pr, Local type – Sharp AY-XP9RMR-AE-X9RMR User Manual
Page 14: R410a, Local air conditioner new, Features cool/dry

13
Local Air Conditioner
NEW
CV-P10PR
R410A
Air conditioner and ion generator in one portable cabinet, „2 in 1”
This Local Air Conditioner can be used
year around by either pressing the
A/C button on the remote control to
operate in cooling mode, or by pressing
the ION button to operate the Ion
Generator function to continue to have
cleaner air in the room.
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Year-Round Use
Ion Generator
Ion
Generator
Dry
Cooling
Features
Cool/Dry
• Selectable operating modes: Cool, Fan, Dry and Ventilation
• Auto-Swing Louvers
• 3-step fan speed and Turbo Cool function
(Standard: EN 14511)
Model
CV-P10PR
2.5
2.6
Cooling operation
Capacity (kW)
EER
A
Model
Indoor
CV-P10PR
Capacity
Cooling
kW
2.5
Power Supply
V/Phase/Hz
220 – 240-single/50
Running Current
A
4.2
Power Input
W
960
EER*1
2.6
Energy Effi ciency Class
A
Hourly Electricity Consumption*2
kWh/60
1.0
Stand-by Power
Consumption
„ON Timer” Off
W
< 0.5
„ON Timer” On
W
< 1.0
Model
Indoor
CV-P10PR
Sound Pressure Level*3 (Hi/Lo)
dB(A)
52/48
Sound Power Level (Hi)
dB(A)
65
Airfl ow Volume (Hi)
m3/min
5.8
Moisture Removal
litter/day
24
Dimensions (WxHxD)
mm
500x830x450
Weight
kg
42
Refrigerant (GWP*4)
kgCO
2
eq.
R410A (1975)
Operation Range
°C
18 – 40
*1 According to EN14511
*2 Energy consumption “X,Y” kWh per 60 minutes,based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Sound pressure level is measured according to JIS C 9612.
*4 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fl uid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fl uid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than
1 kg of CO
2
, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
ON / OFF
LOCAL TYPE
- AY-XPC9JR - AE-X9JR AY-X12RSR-AE-X12RSR AY-XP9LSR - AE-X9LSR CV-P09FR AY-XPC12RR-AE-X12RR AY-XPM7PHR AE-XM30GR AY-XP12RMR-AE-X12RMR AY-XPC12JR - AEX12JR AE-XM24HR AY-X12PSR - AE-X12PSR AY-XPC9RR-AE-X9RR AE-X3M18JR AY-XPC12PHR - AE-X12PHR AY-XPC18LR - AE-X18LR AY-X9PSR - AE-X9PSR AY-X9RSR-AE-X9RSR CV-P10PR AY-XP24LR - AE-X24LR AY-XP12LSR - AE-X12LSR AY-XPC7JR - AE-X7JR AY-XPC9PHR - AE-X9PHR