Inverter, Ay-x9/12psr, R410a – Sharp AY-XP9RMR-AE-X9RMR User Manual
Page 11: Standard new, Specifi cation

10
Standard
NEW
AY-X9/12PSR
Features
Cool/Dry/Heat
Outdoor unit
AE-X9PSR AE-X12PSR
R410A
• Brand-New Design
• High SEER
• Full Power Mode
Model
AY-X9PSR
2.60 (1.00 – 3.10)
2.60 (1.00 – 3.80)
5.7
3.8
Cooling operation
Heating operation
Capacity (kW)
(Min. – Max.)
Capacity (kW)
(Min. – Max.)
SEER
SCOP
AY-X12PSR
3.50 (1.05 – 3.70)
4.00 (1.05 – 4.50)
5.7
3.8
A
A
+A
+A
Specifi cation
Model
Indoor
AY-X9PSR
AY-X12PSR
Outdoor
AE-X9PSR
AE-X12PSR
Preformance*1
Cooling
Energy Effi ciency Class
A+
A+
SEER
5.7
5.7
Pdesign
kW
2.6
3.5
Capacity (Min. – Max.)
kW
2.60 (1.00 – 3.10)
3.50 (1.05 – 3.70)
Input (Min. – Max.)
W
760 (290 – 1,100)
1,060 (290 – 1,330)
Annual electricity consumption*2
kWh/a
161
215
Heating
(Average
Climate)
Energy Effi ciency Class
A
A
SCOP
3.8
3.8
Pdesign
kW
2.6
3.5
Capacity (Min. – Max.)
kW
2.60 (1.00 – 3.80)
3.50 (1.05 – 4.50)
Input (Min. – Max.)
W
680 (290 – 1,400)
1,010 (290 – 1,700)
Annual electricity consumption*2
kWh/a
959
1,290
Nominal Effi ciency*3
EER
3.42
3.40
COP
3.82
3.47
Nominal Current*3
Cooling
A
3.5
4.7
Heating
A
3.1
4.6
Sound Pressure Level*4 (Cool)
Indoor (Hi/Lo)
dB(A)
38/26
38/26
Outdoor
db(A)
50
52
Sound Power Level (Cool)
Indoor (Hi)
54
57
Outdoor
60
62
Airfl ow Volume (Hi, Cool)
m3/min
10.0
10.0
Operation Range (Outdooor)
Coolong
°C
18 – 46
18 – 46
Heating
°C
-7 – 24
-7 – 24
Model
Indoor
AY-X9PSR
AY-X12PSR
Outdoor
AE-X9PSR
AE-X12PSR
Power Supply
Outdoor
V/Phase/Hz 220 – 240/single/50 220 – 240/single/50
Dimensions
Indoor (WxHxD)
mm
800x280x183
800x280x183
Outdoor (WxHxD)
mm
700x551x256
700x551x256
Weight
Indoor
kg
10
10
Outdoor
kg
24
26
Min. – Max. Pipe Lenght
m
1 – 15
1 – 15
Max. Height Difference
m
5
5
Max. Chargless Lenght
m
5
5
Pipe Diameter
Liquid Side
inch
1/4
1/4
Gas Side
inch
3/8
1/2
Refrigerant (GWP*5)
kgCO
2
eq.
R410A (1975)
R410A (1975)
*1 According to EN14825
*2 Energy consumption “XYZ” kWh per year, based on standard test results. Actual energy
consumption will depend on how the appliance is used and where it is located.
*3 According to EN14511
*4 Sound pressure level is measured according to JIS C 9612.
*5 Refrigerant leakage contributes to climate change. Refrigerant with lower global
warming potential (GWP) would contribute less to global warming than a refrigerant
with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fl uid
with a GWP equal to 1975. This means that if 1 kg of this refrigerant fl uid would be leaked
to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg
of CO
2
, over a period of 100 years. Never try to interfere with the refrigerant circuit
yourself or disassemble the product yourself and always ask a professional.
INVERTER
- AY-XPC9JR - AE-X9JR AY-X12RSR-AE-X12RSR AY-XP9LSR - AE-X9LSR CV-P09FR AY-XPC12RR-AE-X12RR AY-XPM7PHR AE-XM30GR AY-XP12RMR-AE-X12RMR AY-XPC12JR - AEX12JR AE-XM24HR AY-X12PSR - AE-X12PSR AY-XPC9RR-AE-X9RR AE-X3M18JR AY-XPC12PHR - AE-X12PHR AY-XPC18LR - AE-X18LR AY-X9PSR - AE-X9PSR AY-X9RSR-AE-X9RSR CV-P10PR AY-XP24LR - AE-X24LR AY-XP12LSR - AE-X12LSR AY-XPC7JR - AE-X7JR AY-XPC9PHR - AE-X9PHR