ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury or death.
DO NOT connect furnace HUM terminal directly to Thermidistat Control

HUM terminal. This will bypass furnace safety controls. See Low Voltage

Wiring Diagrams and notes for proper connection.

!

WARNING

Dehumidify Equipment and Connections

The dry contact output connects to the dehumidify input on variable--speed
furnaces and fan coils. Additional dehumidification is done by controlling the

compressor. A variety of operating modes are available. The dry contact must be
configured for dehumidification in setup Option 19. See Wiring Diagrams for

more information.

Outdoor Temperature Sensor

Outdoor air temperature sensor is included in the box with the Thermidistat
Control. Optimum performance is obtained when an outdoor temperature sensor

is used with the Thermidistat Control. Plan installation so that 2 wires can be run

from Equipment Control Module to an outdoor location, preferably on the north
side of the house or refer to Installation Instructions included with the outdoor

temperature sensor for simplified connection. Sensor can be mounted to outdoor
unit and existing control wires may be used for its connection. Details are

provided in sensor instructions.